Literature DB >> 417427

Xenon enhanced CT for analysis of cerebral integrity, perfusion, and blood flow.

B P Drayer, S K Wolfson, O M Reinmuth, M Dujovny, M Boehnke, E E Cook.   

Abstract

Enhancement of the brain substance for CT evaluation using inhaled Xenon is confirmed. This technique was applied to the study of the normal and the embolized adolescent baboon. Healthy cerebral tissue enhances symmetrically, while abnormal areas show significantly diminished enhancement. At maximal enhancement, an indication of gross comparative cerebral perfusion to obtained. By obtaining serial CT scans over a 10 minute time interval, the clearance rate of Xenon (cerebral blood flow) may be evaluated. Xenon-enhanced CT enables a visual and numerical analysis of both brain morphology and physiology.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 417427     DOI: 10.1161/01.str.9.2.123

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  15 in total

1.  Physiologic changes in regional cerebral blood flow defined by xenon-enhanced CT scanning.

Authors:  B P Drayer; S K Wolfson; M Boehnke; M Dujovny; A E Rosenbaum; E E Cook
Journal:  Neuroradiology       Date:  1978       Impact factor: 2.804

2.  [Development of neuroradiology. From the visualization of bones to molecular imaging].

Authors:  W Reith
Journal:  Radiologe       Date:  2005-04       Impact factor: 0.635

3.  Recirculation of inhaled xenon does not alter lung CT density.

Authors:  Jeffrey B Hoag; Matthew Fuld; Robert H Brown; Brett A Simon
Journal:  Acad Radiol       Date:  2007-01       Impact factor: 3.173

4.  Arterial spin-labeling MRI can identify the presence and intensity of collateral perfusion in patients with moyamoya disease.

Authors:  Greg Zaharchuk; Huy M Do; Michael P Marks; Jarrett Rosenberg; Michael E Moseley; Gary K Steinberg
Journal:  Stroke       Date:  2011-07-28       Impact factor: 7.914

Review 5.  Interrogating Metabolism in Brain Cancer.

Authors:  Travis C Salzillo; Jingzhe Hu; Linda Nguyen; Nicholas Whiting; Jaehyuk Lee; Joseph Weygand; Prasanta Dutta; Shivanand Pudakalakatti; Niki Zacharias Millward; Seth T Gammon; Frederick F Lang; Amy B Heimberger; Pratip K Bhattacharya
Journal:  Magn Reson Imaging Clin N Am       Date:  2016-11       Impact factor: 2.266

6.  Xenon CT measurement of cerebral blood flow in hydrocephalus.

Authors:  P Maeder; N de Tribolet
Journal:  Childs Nerv Syst       Date:  1995-07       Impact factor: 1.475

7.  Tomographic cerebral blood flow measurement using xenon inhalation and serial CT scanning: normal values and its validity.

Authors:  H Segawa
Journal:  Neurosurg Rev       Date:  1985       Impact factor: 3.042

8.  Sixty-four-section CT cerebral perfusion evaluation in patients with carotid artery stenosis before and after stenting with a cerebral protection device.

Authors:  F Gaudiello; V Colangelo; F Bolacchi; M Melis; R Gandini; F G Garaci; V Cozzolino; R Floris; G Simonetti
Journal:  AJNR Am J Neuroradiol       Date:  2008-02-22       Impact factor: 3.825

9.  Cerebrovascular insufficiency as the criterion for revascularization procedures in selected patients: a correlation study of xenon contrast-enhanced CT and PWI.

Authors:  Gerrit Alexander Schubert; Carolin Weinmann; Marcel Seiz; Lars Gerigk; Christel Weiss; Peter Horn; Claudius Thomé
Journal:  Neurosurg Rev       Date:  2008-09-13       Impact factor: 3.042

10.  Reversibility of cerebral ischaemia. Dynamic and xenon computed tomography study on ischaemic cerebrovascular disease.

Authors:  H Ujiie; A Oikawa; K Satoh; H Onda; M Kagawa; K Takakura; Y Kakinoki; Y Ono; N Kobayashi
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.