Literature DB >> 416446

Water/air mass stopping power ratios for megavoltage photon and electron beams.

A E Nahum.   

Abstract

Water/air mass stopping power ratios have been calculated for 5, 10, 20 and 30 MeV electron beams and various photon beams from 60Co to 31 MV betatron. The stopping power ratios have been evaluated by applying a modified version of the Spencer-Attix theory to depth-dependent electron flux spectra computed by the Monte Carlo method. Results are presented for three values of the cavity size parameter delta, 0.001, 0.01 and 0.1 MeV, and also for a Bragg-Gray cavity. For the electron beams, the results are compared to Berger's comprehensive computations. In the case of the photon beams, such a rigorous evaluation of the stopping power ratio has not been carried out previously. It is shown that the currently used approximate Bragg-Gray ratios are as much as 2% too low for high energy photon beams, and that there is a difference of about 1% between values for betatron (thin target) and linac (thick target) beams of the same maximum photon energy.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 416446     DOI: 10.1088/0031-9155/23/1/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Average stopping powers for electron and photon sources for radiobiological modeling and microdosimetric applications.

Authors:  Oleg N Vassiliev; Stephen F Kry; David R Grosshans; Radhe Mohan
Journal:  Phys Med Biol       Date:  2018-03-02       Impact factor: 3.609

2.  Future directions on low-energy radiation dosimetry.

Authors:  G Massillon-Jl
Journal:  Sci Rep       Date:  2021-05-19       Impact factor: 4.379

3.  Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams.

Authors:  Stephen M Seltzer; Paul M Bergstrom
Journal:  J Res Natl Inst Stand Technol       Date:  2003-10-01

4.  The influence of field size on stopping-power ratios in- and out-of-field: quantitative data for the BrainLAB m3 micro-multileaf collimator.

Authors:  Michael Taylor; Tanya Kairn; Tomas Kron; Leon Dunn; Peter N Johnston; Rick D Franich
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

5.  Use of 3D printers to create a patient-specific 3D bolus for external beam therapy.

Authors:  Sarah Burleson; Jamie Baker; An Ting Hsia; Zhigang Xu
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

6.  Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements.

Authors:  N Singh; N K Painuly; L N Chaudhari; A Chairmadurai; T Verma; D Shrotiya; C P Bhatt
Journal:  J Biomed Phys Eng       Date:  2018-09-01

Review 7.  Monte Carlo simulations in radiotherapy dosimetry.

Authors:  Pedro Andreo
Journal:  Radiat Oncol       Date:  2018-06-27       Impact factor: 3.481

8.  Evaluation of beam hardening and photon scatter by brass compensator for IMRT.

Authors:  Shimpei Hashimoto; Katsuyuki Karasawa; Yukio Fujita; Hisayuki Miyashita; Weishan Chang; Toru Kawachi; Tetsurou Katayose; Nao Kobayashi; Etsuo Kunieda; Hidetoshi Saitoh
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

9.  Dosimetric comparison of 4 MeV and 6 MeV electron beams for total skin irradiation.

Authors:  So-Yeon Park; Beom Seok Ahn; Jong Min Park; Sung-Joon Ye; Il Han Kim; Jung-In Kim
Journal:  Radiat Oncol       Date:  2014-09-06       Impact factor: 3.481

  9 in total