Literature DB >> 415542

81mKr ventilation and 99mTc perfusion scans in chest disease: comparison with standard radiographs.

F Fazio, J P Lavender, R E Steiner.   

Abstract

In 75 patients with various pulmonary disorders, ventilation and perfusion scans were obtained in multiple views with the 81mKr/99mTc technique and compared with an evaluation of regional ventilation and perfusion derived from the standard chest radiograph. In emphysema, the chest film correlated poorly with ventilation-perfusion scans, showing a trend to underestimate the functional impairment. In chronic bronchitis and asthma, large segmental defects observed on both ventilation and perfusion scans were associated with a normal chest radiograph. Typical findings in pulmonary embolism were segmental defects on perfusion scan with normal ventilation scan and clear lung fields on the chest film. In chronic left heart disease, plain films were inaccurate in predicting alteration of the base-to-apex perfusion gradient observed on the scan.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 415542     DOI: 10.2214/ajr.130.3.421

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Proceedings of the Thoracic Society. A meeting held in Oxford on 6--7 July 1978. Summaries of papers.

Authors: 
Journal:  Thorax       Date:  1978-10       Impact factor: 9.139

2.  Lung scan abnormalities in asthma and their correlation with lung function.

Authors:  P Vernon; G H Burton; W A Seed
Journal:  Eur J Nucl Med       Date:  1986

3.  Effects of acute and long-term bronchodilator treatment on regional lung function in asthma assessed with krypton-81m and technetium-99m-labelled macroaggregates.

Authors:  A R Sovijärvi; L Pöyhönen; L Kellomäki; A Muittari
Journal:  Thorax       Date:  1982-07       Impact factor: 9.139

Review 4.  New imaging techniques: their relation to conventional radiology.

Authors:  R E Steiner
Journal:  Br Med J (Clin Res Ed)       Date:  1982-05-29

5.  Ventilation imaging with Kr-81m. A comparison with Xe-133.

Authors:  T R Miller; D R Biello; J I Lee; H H Davis; A G Mattar; G J Ehrhardt; B A Siegel
Journal:  Eur J Nucl Med       Date:  1981-01

6.  Studies of regional ventilation in asthma using 81mKr.

Authors:  F Fazio; A Palla; A Santolicandro; S Solfanelli; E Fornai; C Giuntini
Journal:  Lung       Date:  1979       Impact factor: 2.584

7.  Computer analysis of ventilation-perfusion scans for detection and assessment of lung disease.

Authors:  G H Burton; W A Seed; P Vernon
Journal:  Thorax       Date:  1985-07       Impact factor: 9.139

8.  Observations on the mechanism of hypoxaemia in acute minor pulmonary embolism.

Authors:  G H Burton; W A Seed; P Vernon
Journal:  Br Med J (Clin Res Ed)       Date:  1984-08-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.