Abstract
The complement system can be activated by many factors, including immune complexes, leading to the generation of biologically active split products like C5a anaphylatoxin. This study presents a technique which may be used for measuring C5a activity in human serum. The tetanus-anti-tetanus immune complex and aggregated human IgG were used as model activators of the complement cascade. The C5a activity was measured by C5a-induced chemiluminescence of granulocytes; furthermore, a radioimmunoassay was used to detect the C5a peptide. There was a strongly positive correlation between the two assay systems. The described method should be useful as an alternative means of detecting complement activation in the serum of patients with inflammatory diseases.Entities:
Mesh:
Substances:
Year: 1985 PMID: 4096529 DOI: 10.1007/BF00412494
Source DB: PubMed Journal: Arch Dermatol Res ISSN: 0340-3696 Impact factor: 3.017