Literature DB >> 4094554

A method for localizing high-resolution NMR spectra from human subjects.

P Styles, C A Scott, G K Radda.   

Abstract

Several methods are available for the localization of high-resolution spectra. When the sample is a human subject, it may be difficult to realize a viable experimental protocol because the size and geometry of the subject often conflict with efficient probe design. In this paper a spectroscopic localization method is described which is based on the method of rotating frame imaging. A novel surface-coil probe has been developed so that this experiment can be performed on a large sample. 31P spectra from the thorax of a human subject are presented in which signals from liver and intercostal muscle are resolved. These data demonstrate that spatially resolved spectra of metabolites in vivo may be obtained in a time that is acceptable for patient examination.

Entities:  

Mesh:

Year:  1985        PMID: 4094554     DOI: 10.1002/mrm.1910020408

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Spatial localisation of NMR signals and electrical scanning of sensitive regions by the magnetic focusing method.

Authors:  K Tanaka; Y Yamada; Z Abe
Journal:  Med Biol Eng Comput       Date:  1992-07       Impact factor: 2.602

2.  Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications.

Authors:  M Alfonsetti; V Clementi; S Iotti; G Placidi; R Lodi; B Barbiroli; A Sotgiu; M Alecci
Journal:  MAGMA       Date:  2004-12-30       Impact factor: 2.310

Review 3.  Magnetic resonance spectroscopy in the recognition of metabolic disease.

Authors:  R D Griffiths; R H Edwards
Journal:  J Inherit Metab Dis       Date:  1987       Impact factor: 4.982

4.  Evaluation of coils for imaging histological slides: signal-to-noise ratio and filling factor.

Authors:  Dung Minh Hoang; Evelyn B Voura; Chao Zhang; Latifa Fakri-Bouchet; Youssef Zaim Wadghiri
Journal:  Magn Reson Med       Date:  2013-07-15       Impact factor: 4.668

5.  Quantitative studies of human cardiac metabolism by 31P rotating-frame NMR.

Authors:  M J Blackledge; B Rajagopalan; R D Oberhaensli; N M Bolas; P Styles; G K Radda
Journal:  Proc Natl Acad Sci U S A       Date:  1987-06       Impact factor: 11.205

6.  Surface coil localization of 31P NMR signals from orthotopic human kidney and liver.

Authors:  T Jue; D L Rothman; J A Lohman; E W Hughes; C C Hanstock; R G Shulman
Journal:  Proc Natl Acad Sci U S A       Date:  1988-02       Impact factor: 11.205

7.  Acute intestinal ischemia studies by phosphorus nuclear magnetic resonance spectroscopy.

Authors:  H Blum; J J Summers; M D Schnall; C Barlow; J S Leigh; B Chance; G P Buzby
Journal:  Ann Surg       Date:  1986-07       Impact factor: 12.969

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.