Literature DB >> 409267

Structural changes in porcine xenografts used as substitute cardiac valves. Gross and histologic observations in 51 glutaraldehyde-preserved Hancock valves in 41 patients.

T L Spray, W C Roberts.   

Abstract

Gross and histologic changes are described in 51 Hancock glutaraldehyde-preserved porcine heterograft bioprostheses from 41 patients: 33 valves from 25 patients had been in place for less than 2 months ("early") and 18 valves from 17 patients were examined at later periods up to 75 months ("late") after implantation. The major gross changes were thrombosis (five bioprostheses) and degeneration (three bioprotheses) of the cusps. Major histologic changes observed in 44 bioprostheses (26 early and 18 late) examined histologically were: (1) fibrin deposits on inflow and outflow surfaces of the cusps; (2) inflammatory cell infiltrates; (3) histiocyte deposition; (4) giant cell formation, and (5) focal disruption of the fibrocollagenous structure of the cusps. These observations indicate that porcine bioprostheses are not biologically inert in the human circulation. However, valve failure is rare at the implantation periods studied.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 409267     DOI: 10.1016/0002-9149(77)90153-9

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  18 in total

Review 1.  Ectopic calcification: gathering hard facts about soft tissue mineralization.

Authors:  C M Giachelli
Journal:  Am J Pathol       Date:  1999-03       Impact factor: 4.307

2.  Observations on glutaraldehyde-treated heterologous cardiac valves.

Authors:  E Bodnar; E G Olsen; D N Ross
Journal:  Thorax       Date:  1979-12       Impact factor: 9.139

3.  Tissue-engineered fibrin-based heart valve with a tubular leaflet design.

Authors:  Miriam Weber; Eriona Heta; Ricardo Moreira; Valentine N Gesche; Thomas Schermer; Julia Frese; Stefan Jockenhoevel; Petra Mela
Journal:  Tissue Eng Part C Methods       Date:  2013-10-19       Impact factor: 3.056

4.  Rapidly deteriorated failure of Carpentier-Edwards porcine bioprosthesis caused by three detached commissures: report of a case.

Authors:  Y Terada; Y Wanibuchi
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

5.  Echocardiographic features in spontaneous disruption of implanted tissue aortic valves.

Authors:  J M McComb; N P Campbell; C M Hanna; J Cleland
Journal:  Br Heart J       Date:  1984-03

6.  Alloplastic materials for heart-valve prostheses.

Authors:  P Baurschmidt; M Schaldach
Journal:  Med Biol Eng Comput       Date:  1980-07       Impact factor: 2.602

7.  Mitral valve annuloplasty: results in an underdeveloped population.

Authors:  M J Antunes; R H Kinsley
Journal:  Thorax       Date:  1983-10       Impact factor: 9.139

8.  The susceptibility of bioprosthetic heart valve leaflets to oxidation.

Authors:  Abigail J Christian; Hongqiao Lin; Ivan S Alferiev; Jeanne M Connolly; Giovanni Ferrari; Stanley L Hazen; Harry Ischiropoulos; Robert J Levy
Journal:  Biomaterials       Date:  2013-12-18       Impact factor: 12.479

9.  Biochemical differences between dystrophic calcification of cross-linked collagen implants and mineralization during bone induction.

Authors:  M E Nimni; S Bernick; D T Cheung; D C Ertl; S K Nishimoto; W J Paule; C Salka; B S Strates
Journal:  Calcif Tissue Int       Date:  1988-05       Impact factor: 4.333

10.  Tricuspid valve replacement with the St. Jude Medical valve.

Authors:  S Aoyagi; Y Nishi; T Kawara; A Oryoji; H Hara; K Kosuga; K Ohishi
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.