Literature DB >> 4090084

[Comparative experimental studies with biologic materials for replacement of the anterior cruciate ligament].

R Ascherl, W Siebels, B Kobor, K Geissdörfer, M L Schmeller, H Lichti, W Fraefel, G Blümel.   

Abstract

Allogeneic and xenogeneic biological tendon and ligament materials for ligament replacement were tested in the knee of rabbits and sheep. In-vitro and ex-vivo biomechanical tests as well as micromorphological investigations following implantation were performed. The preparation procedure mainly consists in cross linking of collagen by dicarboxylic acids (DC). Modifications in the method induce changes in the biomechanical stability also after implantation. Sheep with autologous patellar tendons substitutions and glutaraldehyde (GA) fixed bovine tendons served as controls. Because of biocompatibility reasons the later seem to be not yet suitable for clinical applications. The DC-tendons need for improved midterm stability prior to clinical implantations; the biocompatibility appears to be excellent.

Entities:  

Mesh:

Year:  1985        PMID: 4090084     DOI: 10.1007/BF02587978

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  26 in total

1.  The anterior cruciate ligament: a technique of repair and reconstruction.

Authors:  J L Marshall; R F Warren; T L Wickiewicz; B Reider
Journal:  Clin Orthop Relat Res       Date:  1979-09       Impact factor: 4.176

2.  [Experimental replacement of the anterior cruciate ligament of the knee joint by transplants of different type].

Authors:  A Salamon; F Mayer; G Temes
Journal:  Bruns Beitr Klin Chir (1971)       Date:  1970-04

3.  Experiences with modified bovine carotid arteries in arterial surgery.

Authors:  D M Rosenberg; B A Glass; N Rosenberg; M R Lewis; W A Dale
Journal:  Surgery       Date:  1970-12       Impact factor: 3.982

4.  Effect of exercise upon ligament strength.

Authors:  A Adams
Journal:  Res Q       Date:  1966-05

5.  Tendon grafting with glutaraldehyde fixed material.

Authors:  W C McMaster; J Kouzelos; S Liddle; T R Waugh
Journal:  J Biomed Mater Res       Date:  1976-03

6.  [Uses of autologous skin in traumatology].

Authors:  J Müller; R Stotz; B Roth
Journal:  Chirurg       Date:  1982-04       Impact factor: 0.955

7.  [Arthroscopic studies of pedicled autogenic tendon grafts for the replacement of the anterior cruciate ligament].

Authors:  A Wentzensen; S Weller
Journal:  Chirurg       Date:  1982-04       Impact factor: 0.955

8.  Experimental investigations of primary healing and remodeling of lyophilized connective tissue dependent on the graft bed.

Authors:  C J Wirth; M Jäger
Journal:  Arch Orthop Trauma Surg       Date:  1980

9.  [Alloplastic grafting of ligaments with carbon-fibres (author's transl)].

Authors:  R Neugebauer; C Burri
Journal:  Unfallchirurgie       Date:  1981-12

10.  The role of flexible carbon-fibre implants as tendon and ligament substitutes in clinical practice. A preliminary report.

Authors:  D H Jenkins; B McKibbin
Journal:  J Bone Joint Surg Br       Date:  1980-11
View more
  1 in total

1.  Measurement of stress-strain relationship and stress relaxation in various synthetic ligaments.

Authors:  R Kdolsky; R Reihsner; R Schabus; R J Beer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1994       Impact factor: 4.342

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.