Literature DB >> 4086640

Simultaneous high-performance liquid chromatographic stability-indicating analysis of acetaminophen and codeine phosphate in tablets and capsules.

W R Sisco, C T Rittenhouse, L A Everhart.   

Abstract

A high-performance liquid chromatographic method has been developed for the simultaneous determination of acetaminophen and codeine phosphate for product stability studies, and release and dissolution testing of tablets and capsules. The reversed-phase method utilizes UV detection at 214 nm, a C18 column and requires a maximum of 10 min per analysis. The method has been validated for use with products containing as much as 500 mg of acetaminophen and as little as 7.5 mg of codeine phosphate. The known potential degradation products, p-aminophenol, codeine N-oxide, and codeinone are separated for quantitation simultaneous with the parent compounds. The method has been shown to be linear, reproducible, specific, sensitive and rugged.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4086640     DOI: 10.1016/s0021-9673(01)92459-8

Source DB:  PubMed          Journal:  J Chromatogr


  1 in total

1.  Biotransformation of (-)-codeinone to (-)-codeine byPapaver somniferum cells immobilized in reticulate polyurethane foam.

Authors:  P Corchete; M M Yeoman
Journal:  Plant Cell Rep       Date:  1989-02       Impact factor: 4.570

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.