Literature DB >> 4086433

Headspace gas chromatographic method for determination of methyl bromide in food ingredients.

J W DeVries, J M Broge, J P Schroeder, R H Bowers, P A Larson, N M Burns.   

Abstract

A headspace gas chromatographic (GC) method, which can be automated, has been developed for determination of methyl bromide. This method has been applied to wheat, flour, cocoa, and peanuts. Samples to be analyzed are placed in headspace sample vials, water is added, and the vials are sealed with Teflon-lined septa. After an appropriate equilibration time at 32 degrees C, the samples are analyzed within 10 h. A sample of the headspace is withdrawn and analyzed on a gas chromatograph equipped with an electron capture detector (ECD). Methyl bromide levels were quantitated by comparison of peak area with a standard. The standard was generated by adding a known amount of methyl bromide to a portion of the matrix being analyzed and which was known to be methyl bromide free. The detection limit of the method was 0.4 ppb. The coefficient of variation (CV) was 6.5% for wheat, 8.3% for flour, 3.3% for cocoa, and 11.6% for peanuts.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4086433

Source DB:  PubMed          Journal:  J Assoc Off Anal Chem        ISSN: 0004-5756


  1 in total

1.  Residues of methyl bromide and sulfuryl fluoride in manufacturer-packaged household foods following fumigation.

Authors:  R H Scheffrahn; L Bodalbhai; N Y Su
Journal:  Bull Environ Contam Toxicol       Date:  1992-06       Impact factor: 2.151