| Literature DB >> 4081725 |
R G McGregor, W B Walker, E G Létourneau.
Abstract
Radon and radon daughter concentrations have been measured in 33 "energy-efficient" homes in a small subdivision in Kanata, Ontario. Integrated radon measurements were determined over three month periods for a year using solid state nuclear track detectors. Radon and radon daughter grab sample determinations were made during corresponding periods and confirm the distributions of the integrated radon measurements. Annual average individual home radon concentrations show an 8 fold concentration range between homes. This variability in radon concentrations is not reflected in the range of air exchange rates for the homes. A distinct seasonal variation is noted for the median values of the radon and radon daughter concentrations and the equilibrium factor F in the dwellings.Mesh:
Substances:
Year: 1985 PMID: 4081725 DOI: 10.1016/0048-9697(85)90228-1
Source DB: PubMed Journal: Sci Total Environ ISSN: 0048-9697 Impact factor: 7.963