A microscope diffusion chamber for the determination of the equilibrium and non-equilibrium osmotic response of individual cells.

J J McGrath.   

Abstract

A microscope diffusion chamber has been developed which allows direct observation of the dynamic osmotic response of individual cells in micro-volume suspensions. Continuous observation of stationary cells is possible including short experimental times while the extracellular chemical composition is changed. Multiple changes of solute type or concentration are easily imposed upon a single sample volume. Response times are a function of chamber configuration but response times as low as 1-10 s are possible with negligible solute concentration gradients within the sample region. The chamber is simple and economical to construct and use. It is the size of an ordinary glass microslide and it can be adapted easily to any common laboratory microscope. All standard optical techniques may be used with the chamber. Construction details and operating characteristics including important limitations are discussed. Example photomicrographs and osmotic data are included.

Mesh:

Substances:

Year:  1985        PMID: 4078888     DOI: 10.1111/j.1365-2818.1985.tb02641.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  11 in total

1.  An Application of Stream Imaging Technique in the Study of Osmotic Behaviors of Multiple Cells.

Authors:  Hsiu-Hung Chen; Edward H Lin; Shelly Heimfeld; Dayong Gao
Journal:  Cell Preserv Technol       Date:  2008-06-01

Review 2.  Microfluidics for cryopreservation.

Authors:  Gang Zhao; Jianping Fu
Journal:  Biotechnol Adv       Date:  2017-01-30       Impact factor: 14.227

3.  Controlled loading of cryoprotectants (CPAs) to oocyte with linear and complex CPA profiles on a microfluidic platform.

Authors:  Yun Seok Heo; Ho-Joon Lee; Bryan A Hassell; Daniel Irimia; Thomas L Toth; Heidi Elmoazzen; Mehmet Toner
Journal:  Lab Chip       Date:  2011-09-01       Impact factor: 6.799

4.  Determination of the Membrane Permeability to Water of Human Vaginal Mucosal Immune Cells at Subzero Temperatures Using Differential Scanning Calorimetry.

Authors:  Zhiquan Shu; Sean M Hughes; Cifeng Fang; Zhiyuan Hou; Gang Zhao; Michael Fialkow; Gretchen Lentz; Florian Hladik; Dayong Gao
Journal:  Biopreserv Biobank       Date:  2016-03-15       Impact factor: 2.300

5.  A microfluidic perfusion approach for on-chip characterization of the transport properties of human oocytes.

Authors:  Gang Zhao; Zhiguo Zhang; Yuntian Zhang; Zhongrong Chen; Dan Niu; Yunxia Cao; Xiaoming He
Journal:  Lab Chip       Date:  2017-03-29       Impact factor: 6.799

6.  A Microfluidic Study of Megakaryocytes Membrane Transport Properties to Water and Dimethyl Sulfoxide at Suprazero and Subzero Temperatures.

Authors:  Hsiu-Yang Tseng; Sijie Sun; Zhiquan Shu; Weiping Ding; Jo-Anna Reems; Dayong Gao
Journal:  Biopreserv Biobank       Date:  2011-12       Impact factor: 2.300

7.  Slow and steady cell shrinkage reduces osmotic stress in bovine and murine oocyte and zygote vitrification.

Authors:  D Lai; J Ding; G W Smith; G D Smith; S Takayama
Journal:  Hum Reprod       Date:  2014-10-29       Impact factor: 6.918

8.  Synergistic Development of Biochips and Cell Preservation Methodologies: A Tale of Converging Technologies.

Authors:  Shangping Wang; Gloria D Elliott
Journal:  Curr Stem Cell Rep       Date:  2017-01-21

9.  Dual dependence of cryobiogical properties of Sf21 cell membrane on the temperature and the concentration of the cryoprotectant.

Authors:  Jianye Wang; Kaixuan Zhu; Gang Zhao; Jian Ren; Cui Yue; Dayong Gao
Journal:  PLoS One       Date:  2013-09-04       Impact factor: 3.240

10.  Determination of the Membrane Transport Properties of Jurkat Cells with a Microfluidic Device.

Authors:  Tianhang Yang; Ji Peng; Zhiquan Shu; Praveen K Sekar; Songjing Li; Dayong Gao
Journal:  Micromachines (Basel)       Date:  2019-11-29       Impact factor: 2.891