Literature DB >> 4078580

A comparison of the changes in suprathreshold apparent contrast in acute and simulated optic neuritis.

M Abrahamsson, J Sjöstrand.   

Abstract

A thin PVC film was used as a diffusion filter together with glass lenses in order to induce a unilateral artificial contrast sensitivity depression in controls. These artificially depressed contrast sensitivity functions were made comparable to those assessed in patients during the recovery phase of their acute unilateral optic neuritis. A technique of subjective suprathreshold contrast matching was used to determine the suprathreshold apparent contrast in patients and controls with acute and simulated optic neuritis respectively. The results showed that differences in apparent contrast between the eyes is proportional to the discrepancy in threshold contrast for high and intermediate spatial frequencies in patients with optic neuritis. For low frequencies the apparent contrast difference was independent of threshold differences. Contrast vision of controls with simulated optic neuritis did not show this frequency dependency. There was also a discrepancy in visual acuity between the two groups. Generally the control with artificially depressed contrast sensitivity functions has a letter acuity value lower than that of the optic neuritis patient with a corresponding CSF depression.

Entities:  

Mesh:

Year:  1985        PMID: 4078580      PMCID: PMC1028575          DOI: 10.1136/jnnp.48.11.1147

Source DB:  PubMed          Journal:  J Neurol Neurosurg Psychiatry        ISSN: 0022-3050            Impact factor:   10.154


  9 in total

1.  Effective contrast constancy and linearity of contrast sensation.

Authors:  J J Kulikowski
Journal:  Vision Res       Date:  1976       Impact factor: 1.886

2.  Contrast-coding in amblyopia. II. On the physiological basis of contrast recruitment.

Authors:  R F Hess
Journal:  Proc R Soc Lond B Biol Sci       Date:  1983-02-22

3.  Contrast-coding in amblyopia. I. Differences in the neural basis of human amblyopia.

Authors:  R F Hess; A Bradley; L Piotrowski
Journal:  Proc R Soc Lond B Biol Sci       Date:  1983-02-22

4.  Contrast matching data predicted from contrast increment thresholds.

Authors:  W H Swanson; H R Wilson; S C Giese
Journal:  Vision Res       Date:  1984       Impact factor: 1.886

5.  Contrast constancy: deblurring in human vision by spatial frequency channels.

Authors:  M A Georgeson; G D Sullivan
Journal:  J Physiol       Date:  1975-11       Impact factor: 5.182

6.  Suprathreshold vision in acute optic neuritis.

Authors:  J Sjöstrand; M Abrahamsson
Journal:  J Neurol Neurosurg Psychiatry       Date:  1982-03       Impact factor: 10.154

7.  Contrast perception above threshold is only minimally impaired in human amblyopia.

Authors:  R F Hess; A Bradley
Journal:  Nature       Date:  1980-10-02       Impact factor: 49.962

8.  Contrast sensitivity in macular disease using a small-field and a large-field TV-system.

Authors:  J Sjöstrand
Journal:  Acta Ophthalmol (Copenh)       Date:  1979-10

9.  Contrast vision and optic neuritis: neural blurring.

Authors:  R F Hess
Journal:  J Neurol Neurosurg Psychiatry       Date:  1983-11       Impact factor: 10.154

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.