Literature DB >> 4075216

Recurrence of pulsus alternans after fentanyl injection in a patient with aortic stenosis and congestive heart failure.

A B Freeman, R A Steinbrook.   

Abstract

Following aortic valve replacement in a patient with aortic stenosis and cardiac failure, marked pulsus alternans recurred immediately after intravenous injection of 0.5 mg fentanyl, without concomitant changes in heart rate, mean left atrial pressure, or the electrocardiogram. Pulsus alternans is known to occur in association with heart failure and aortic stenosis, but has not been reported previously in response to anaesthetic drugs. Mechanisms of pulsus alternans are discussed, and the possible contributory role of fentanyl is considered.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4075216     DOI: 10.1007/BF03011415

Source DB:  PubMed          Journal:  Can Anaesth Soc J        ISSN: 0008-2856


  9 in total

1.  Studies on Starling's law of the heart. VI. Relationships between left ventricular enddiatolic volume and stroke volume in man with observations on the mechanism of pulsus alternans.

Authors:  W L GLEASON; E BRAUNWALD
Journal:  Circulation       Date:  1962-05       Impact factor: 29.690

2.  Aortic stenosis.

Authors:  E W HANCOCK; P R FLEMING
Journal:  Q J Med       Date:  1960-04

3.  Pulsus alternans in aortic stenosis; hemodynamic observations in 50 patients studied by left heart catheterization.

Authors:  T COOPER; E BRAUNWALD; A G MORROW
Journal:  Circulation       Date:  1958-07       Impact factor: 29.690

4.  Orthostatic factors in pulsus alternans.

Authors:  B FRIEDMAN; W M DAILY; R S SHEFFIELD
Journal:  Circulation       Date:  1953-12       Impact factor: 29.690

5.  THE DYNAMICS OF PULSUS ALTERNANS: ALTERNATING END-DIASTOLIC FIBER LENGTH AS A CAUSATIVE FACTOR.

Authors:  J H Mitchell; S J Sarnoff; E H Sonnenblick
Journal:  J Clin Invest       Date:  1963-01       Impact factor: 14.808

6.  Alternating contractility in pulsus alternans studied in the isolated canine heart.

Authors:  M D McGaughey; W L Maughan; K Sunagawa; K Sagawa
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

7.  Plasma catecholamine and cortisol responses to fentanyl--oxygen anesthesia for coronary-artery operations.

Authors:  T H Stanley; L Berman; O Green; D Robertson
Journal:  Anesthesiology       Date:  1980-09       Impact factor: 7.892

8.  Hemodynamic and ventilatory responses to fentanyl, fentanyl-droperidol, and nitrous oxide in patients with acquired valvular heart disease.

Authors:  R K Stoelting; P S Gibbs; C W Creasser; C Peterson
Journal:  Anesthesiology       Date:  1975-03       Impact factor: 7.892

9.  Comparison of fentanyl, sufentanil, and alfentanil anesthesia in patients undergoing valvular heart surgery.

Authors:  J G Bovill; P J Warren; J L Schuller; H B van Wezel; M H Hoeneveld
Journal:  Anesth Analg       Date:  1984-12       Impact factor: 5.108

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.