Literature DB >> 4074595

Efficacy of an implanted automatic defibrillator which had induced atrial fibrillation.

L Jordaens, R Hamerlynck, D L Clement.   

Abstract

A 54 year old man with refractory life threatening ventricular tachycardia was given an automatic defibrillator. The initial system was a transvenous defibrillator coil electrode and this was later modified by implantation of two patch electrodes at thoracotomy. The modified system successfully controlled ventricular tachycardia. On one occasion reversion of ventricular tachycardia by the defibrillator precipitated atrial fibrillation, a previously unreported side effect.

Entities:  

Mesh:

Year:  1985        PMID: 4074595      PMCID: PMC481961          DOI: 10.1136/hrt.54.6.605

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  8 in total

1.  Role of a catheter lead system for transvenous countershock and pacing during electrophysiologic tests: an assessment of the usefulness of catheter shocks for terminating ventricular tachyarrhythmias.

Authors:  L E Waspe; S G Kim; J A Matos; J D Fisher
Journal:  Am J Cardiol       Date:  1983-09-01       Impact factor: 2.778

2.  Amiodarone-induced refractoriness to cardioversion.

Authors:  R N Fogoros
Journal:  Ann Intern Med       Date:  1984-05       Impact factor: 25.391

3.  Treatment of out-of-hospital cardiac arrests with rapid defibrillation by emergency medical technicians.

Authors:  M S Eisenberg; M K Copass; A P Hallstrom; B Blake; L Bergner; F A Short; L A Cobb
Journal:  N Engl J Med       Date:  1980-06-19       Impact factor: 91.245

4.  Implantation of the automatic defibrillator: the subxiphoid approach.

Authors:  L Watkins; M Mirowski; M M Mower; P R Reid; P Freund; A Thomas; M L Weisfeldt; V L Gott
Journal:  Ann Thorac Surg       Date:  1982-11       Impact factor: 4.330

5.  Electrophysiologic and hemodynamic studies in patients resuscitated from cardiac arrest.

Authors:  M E Josephson; L N Horowitz; S R Spielman; A M Greenspan
Journal:  Am J Cardiol       Date:  1980-12-01       Impact factor: 2.778

6.  Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration.

Authors:  R A Winkle; E B Stinson; S M Bach; D S Echt; P Oyer; K Armstrong
Journal:  Circulation       Date:  1984-04       Impact factor: 29.690

7.  Mortality in patients with implanted automatic defibrillators.

Authors:  M Mirowski; P R Reid; R A Winkle; M M Mower; L Watkins; E B Stinson; L S Griffith; C H Kallman; M L Weisfeldt
Journal:  Ann Intern Med       Date:  1983-05       Impact factor: 25.391

8.  Clinical performance of the implantable cardioverter-defibrillator.

Authors:  M Mirowski; P R Reid; M M Mower; L Watkins; E V Platia; L S Griffith; T Guarnieri; A Thomas; J M Juanteguy
Journal:  Pacing Clin Electrophysiol       Date:  1984-11       Impact factor: 1.976

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.