Effect of femoral stem length on stress raisers associated with revision hip arthroplasty.

M M Panjabi, T Trumble, J E Hult, W O Southwick.   

Abstract

The objective of this study was to experimentally determine the optimal length of a femoral component in revision total hip arthroplasty (THA). Embalmed cadaveric femurs were loaded in a physiologic manner, and strains on the lateral cortex were measured. Two kinds of defects were tested to simulate THA after removal of a nail plate and after removal of a loose femoral stem. A drill hole was made in the lateral cortex of the femur to simulate the removal of a nail plate. A reaming defect was made, using flexible reamers to thin the cortex from the lesser trochanter distally to a site corresponding to the tip of a standard femoral component, to simulate THA after removal of a previously inserted femoral stem. Femurs were tested intact, with the defects, and after insertion of femoral components with stem lengths of 100 to 250 mm. The strain increased with the creation of a defect and decreased with the insertion of an implant. For a femur with a defect, the strain was minimized when the stem length extended 1.5 femoral diameters past the defect.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4067703     DOI: 10.1002/jor.1100030407

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  7 in total

1.  Hip painful prosthesis: surgical view.

Authors:  Antonio Spinarelli; Vittorio Patella; Vito Conserva; Giovanni Vicenti; Vito Pesce; Silvio Patella
Journal:  Clin Cases Miner Bone Metab       Date:  2011-05

2.  Reduced femoral component subsidence with improved impaction grafting at revision hip arthroplasty.

Authors:  D W Howie; S A Callary; M A McGee; N C Russell; L B Solomon
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  A review of periprosthetic femoral fractures associated with total hip arthroplasty.

Authors:  Daniel Marsland; Simon C Mears
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-09

Review 4.  Periprosthetic fractures around the femoral stem: overcoming challenges and avoiding pitfalls.

Authors:  Andrew N Fleischman; Antonia F Chen
Journal:  Ann Transl Med       Date:  2015-09

5.  Risk of periprosthetic femur fracture after anterior cortical bone windowing: a mechanical analysis of short versus long cemented stems in pigs.

Authors:  Lance J Wilson; Corey J Richards; Dean Irvine; Armand Tillie; Ross W Crawford
Journal:  Acta Orthop       Date:  2011-11-09       Impact factor: 3.717

6.  Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis.

Authors:  R Michael Meneghini; Nadim J Hallab; Richard A Berger; Joshua J Jacobs; Wayne G Paprosky; Aaron G Rosenberg
Journal:  J Orthop Surg Res       Date:  2006-10-02       Impact factor: 2.359

Review 7.  Efficacy of Lesion Specific Portals in Endoscopic Treatment of Calcaneal Bone Cyst: A Case Report and Literature Review.

Authors:  Young Yi; Jeong Seok Lee; Jahyung Kim; So Young Jin; Sung Hun Won; Jaeho Cho; Dong-Il Chun
Journal:  Medicina (Kaunas)       Date:  2021-01-26       Impact factor: 2.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.