[Can EEG monitoring with the Trend Analyzer replace stump pressure measurement in carotid surgery?].

H Loeprecht, K Wölfle, J Heudorfer, H Reich.   

Abstract

Description of the EEG-trend-analyzer as an intraoperative monitoring during carotis surgery. Criteria for the evaluation of the findings are presented. In a prospective study 92 patients underwent monitoring with the EEG-trend-analyzer as well as the measuring of the internal carotid artery stump pressure. EEG monitoring shows a sensitivity of 100% for ischemic events, compared to 67% for the stump pressure measurement with a threshold of 50 mm Hg. EEG monitoring shows false positive results in 25% but no false negative results. Stump pressure investigation of the internal carotid artery is a very unreliable parameter for cerebral ischemia and inferior to the results of EEG-monitoring.

Entities:  

Mesh:

Year:  1985        PMID: 4058175     DOI: 10.1007/BF01836659

Source DB:  PubMed          Journal:  Langenbecks Arch Chir        ISSN: 0023-8236


  10 in total

1.  Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy.

Authors:  T M Sundt; F W Sharbrough; R E Anderson; J D Michenfelder
Journal:  J Neurosurg       Date:  1974-09       Impact factor: 5.115

2.  Cerebral hemodynamics in carotid surgery.

Authors:  G Boysen
Journal:  Acta Neurol Scand Suppl       Date:  1973

3.  The use of electroencephalographic monitoring during carotid endarterectomy, as an indicator for the application of a temporary by-pass.

Authors:  B M Marshall; W M Lougheed
Journal:  Can Anaesth Soc J       Date:  1969-07

4.  Cerebral Ischemia during carotid endarterectomy with severe but reversible changes.

Authors:  H H Kaufman; E L Reilly; H P Porecha; K G Khalil; G Van Horn
Journal:  Surg Neurol       Date:  1977-04

5.  Hemiparesis following carotid endarterectomy: comparison of monitoring methods.

Authors:  B L Grundy; A C Sanderson; W W Webster; E T Richey; P Procopio; P N Karanjia
Journal:  Anesthesiology       Date:  1981-10       Impact factor: 7.892

6.  Carotid and vertebral artery surgery, EEG monitoring, and the operating room.

Authors:  E M Anderson; A L Carney; L Page
Journal:  Adv Neurol       Date:  1981

7.  Results of electroencephalographic monitoring during 367 carotid endarterectomies. Use of a dedicated minicomputer.

Authors:  K H Chiappa; S R Burke; R R Young
Journal:  Stroke       Date:  1979 Jul-Aug       Impact factor: 7.914

8.  Continuous electroencephalographic monitoring during carotid artery endarterectomy.

Authors:  E J Harris; W H Brown; R N Pavy; W W Anderson; D W Stone
Journal:  Surgery       Date:  1967-09       Impact factor: 3.982

9.  Prognostic value of computerized EEG analysis during carotid endarterectomy.

Authors:  I J Rampil; J A Holzer; D O Quest; S H Rosenbaum; J W Correll
Journal:  Anesth Analg       Date:  1983-02       Impact factor: 5.108

10.  EEG and carotid cutaneous plethysmographic monitoring during carotid reconstructive surgery.

Authors:  B Fuster; W Machado; C Vechi
Journal:  Adv Neurol       Date:  1981
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.