Literature DB >> 4056010

New cause for false-positive results with the cryptococcal antigen test by latex agglutination.

W H Boom, D J Piper, K L Ruoff, M J Ferraro.   

Abstract

The highly specific and sensitive latex agglutination test for cryptococcal antigen detection in cerebrospinal fluid is routine in many hospitals. Contamination of cerebrospinal fluid by a minute amount of syneresis fluid (surface condensation) from agar gave a strongly positive reaction which was heat stable, was not eliminated by pronase treatment, and was not detected by the normal rabbit globulin controls. These observations were valid for three commercially available test kits and could represent a preventable cause of some unexplained false-positive tests despite the use of adequate controls.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4056010      PMCID: PMC268543          DOI: 10.1128/jcm.22.5.856-857.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  DETECTION OF CRYPTOCOCCUS NEOFORMANS ANTIGEN IN BODY FLUIDS BY LATEX PARTICLE AGGLUTINATION.

Authors:  N BLOOMFIELD; M A GORDON; D F ELMENDORF
Journal:  Proc Soc Exp Biol Med       Date:  1963-10

2.  Corrected version specificity of the latex test for cryptococcal antigen: a rapid, simple method for eliminating interference factors.

Authors:  L Stockman; G D Roberts
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

3.  On the structure of the capsular polysaccharide from Cryptococcus neoformans serotype C.

Authors:  A K Bhattacharjee; K J Kwon-Chung; C P Glaudemans
Journal:  Immunochemistry       Date:  1978-09

4.  Specificity of the latex-cryptococcal antigen test.

Authors:  C T Dolan
Journal:  Am J Clin Pathol       Date:  1972-10       Impact factor: 2.493

5.  Control for rheumatoid factor in the latex test for cryptococcosis.

Authors:  J E Bennett; J W Bailey
Journal:  Am J Clin Pathol       Date:  1971-09       Impact factor: 2.493

6.  Diagnosis of cryptococcal meningitis. Value of immunologic detection of cryptococcal antigen.

Authors:  J S Goodman; L Kaufman; M G Koenig
Journal:  N Engl J Med       Date:  1971-08-19       Impact factor: 91.245

7.  Cryptococcal meningitis: diagnostic value of cryptococcal antigen in cerebrospinal fluid.

Authors:  R M Snow; W E Dismukes
Journal:  Arch Intern Med       Date:  1975-09

8.  False positive latex tests for cryptococcal antigen in cerebrospinal fluid.

Authors:  R J Hay; D W Mackenzie
Journal:  J Clin Pathol       Date:  1982-02       Impact factor: 3.411

9.  Diagnostic value of cryptococcal antigen in the cerebrospinal fluid of patients with malignant disease.

Authors:  R L Hopper; E V Perry; V Fainstein
Journal:  J Infect Dis       Date:  1982-06       Impact factor: 5.226

  9 in total
  12 in total

1.  False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

Authors:  Deborah A Wilson; Mary Sholtis; Sharon Parshall; Gerri S Hall; Gary W Procop
Journal:  J Clin Microbiol       Date:  2010-12-15       Impact factor: 5.948

2.  Utility of routine testing of bronchoalveolar lavage fluid for cryptococcal antigen.

Authors:  S M Kralovic; J C Rhodes
Journal:  J Clin Microbiol       Date:  1998-10       Impact factor: 5.948

3.  False-negative cerebrospinal fluid cryptococcal latex agglutination tests for patients with culture-positive cryptococcal meningitis.

Authors:  B P Currie; L F Freundlich; M A Soto; A Casadevall
Journal:  J Clin Microbiol       Date:  1993-09       Impact factor: 5.948

4.  Evaluation of an enzyme immunoassay for detection of cryptococcal capsular polysaccharide antigen in serum and cerebrospinal fluid.

Authors:  U K Frank; S L Nishimura; N C Li; K Sugai; D M Yajko; W K Hadley; V L Ng
Journal:  J Clin Microbiol       Date:  1993-01       Impact factor: 5.948

5.  Effect of potential interference factors on performance of enzyme immunoassay and latex agglutination assay for cryptococcal antigen.

Authors:  H D Engler; Y R Shea
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

6.  False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.

Authors:  L B Blevins; J Fenn; H Segal; P Newcomb-Gayman; K C Carroll
Journal:  J Clin Microbiol       Date:  1995-06       Impact factor: 5.948

7.  Cryptosporidium antigen detection in human feces by reverse passive hemagglutination assay.

Authors:  S C Arya
Journal:  J Clin Microbiol       Date:  1995-06       Impact factor: 5.948

Review 8.  Cryptococcosis in the era of AIDS--100 years after the discovery of Cryptococcus neoformans.

Authors:  T G Mitchell; J R Perfect
Journal:  Clin Microbiol Rev       Date:  1995-10       Impact factor: 26.132

9.  False-positive reactions in the latex agglutination test for Cryptococcus neoformans antigen.

Authors:  J S Heelan; L Corpus; N Kessimian
Journal:  J Clin Microbiol       Date:  1991-06       Impact factor: 5.948

10.  Elimination of false-positive serum reactivity in latex agglutination test for cryptococcal antigen in human immunodeficiency virus-infected population.

Authors:  S Whittier; R L Hopfer; P Gilligan
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.