Literature DB >> 4055594

Hemodynamic effects of anti-G suit inflation in a 1-G environment.

J F Seaworth, T J Jennings, L L Howell, J W Frazier, C D Goodyear, E D Grassman.   

Abstract

This study evaluated effects of various anti-G inflation pressures on cardiac volumes and the relationship of these volume changes to mean arterial pressure changes. Ventricular volumes were calculated using two-dimensional echocardiography. An anti-G suit was inflated to 2, 4, and 6 psi in the standing and supine positions for 10 male subjects. In the supine position, mean arterial pressure increased from base line for all three inflation pressures (P = 0.05). The end-diastolic volume increased after 2-psi inflation (P = 0.03). Cardiac output or stroke volume did not change. After standing, mean arterial pressure (P = 0.002), end-diastolic volume (P = 0.002), and stroke volume (P = 0.05) fell after suit deflation. Peripheral vascular resistance fell in the 2- and 4-psi inflation profiles. In the standing protocol, mean arterial pressure, end-diastolic volume, stroke volume, and cardiac output rose with all three inflation pressures (P less than 0.05). After reclining, heart rate increased (P = 0.02) and mean arterial pressure fell (P less than 0.05) in the 4- and 6-psi inflation profiles after suit deflation. Increases in mean arterial pressure are caused by increases in cardiac preload and cardiac output after inflation of the anti-G suit while subjects were standing. Increased cardiac preload was not consistently seen after inflation while subjects were supine. Changes in end-diastolic volume and mean arterial pressure were dependent on the pressure used to inflate the anti-G suit.

Entities:  

Mesh:

Year:  1985        PMID: 4055594     DOI: 10.1152/jappl.1985.59.4.1145

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  2 in total

1.  Effects of physical exercise and anti-G suit inflation on atrial natriuretic factor plasma level.

Authors:  C Y Guezennec; E Fournier; F X Galen; M Lartigues; F Louisy; J Gutkowska
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

2.  A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves.

Authors:  Maurits K Konings; Henk G Goovaerts; Maarten R Roosendaal; Rienk Rienks; Ferry M Koevoets; Ronald L Bleys; Wolfgang F Buhre; Paul M Dorresteijn; Tim Hesselink; Arthur E Officier; Charles L Hollenkamp; Frank E Rademakers
Journal:  Biomed Eng Online       Date:  2012-08-17       Impact factor: 2.819

  2 in total