Effect of respiratory apparatus on timing and depth of breathing in man.

D L Maxwell, D Cover, J M Hughes.   

Abstract

The effects on breathing of (1) nose-clips, with and without mouthpieces, (2) tube breathing with incremental dead spaces up to 600 ml, and (3) a Venturi mask with a high air inflow reducing the effective dead space to zero were measured with respiratory inductance plethysmography. The effective dead spaces of the lengths of tubing were 25% smaller than their water-displacement volumes. The principal response to the increase in dead space was an increase in VT without any change in frequency or timing. The increase in VE was 16% greater than the ventilation of the effective dead space. The facemask with a high flow of air did not affect the pattern of breathing. External devices alone (nose-clips, mouthpieces) by themselves brought about a significant increase in VT (+10%, P less than 0.05) and a small drop in frequency, which in the case of a nose-clip alone was large enough to be significant (-15%, P less than 0.05). The increase in DS with the change from nasal to oral breathing may have contributed to the accompanying increase in VT; the fall in frequency with the nose-clip alone might have been caused by stimulation of receptors in the trigeminal area.

Entities:  

Mesh:

Year:  1985        PMID: 4048673     DOI: 10.1016/0034-5687(85)90130-6

Source DB:  PubMed          Journal:  Respir Physiol        ISSN: 0034-5687


  4 in total

1.  Implementation of a respiratory drive monitor on a Servo Ventilator.

Authors:  L G Hellström; H Larsson; D Linnarsson
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

Review 2.  Maximising the clinical use of exercise gaseous exchange testing in children with repaired cyanotic congenital heart defects: the development of an appropriate test strategy.

Authors:  A McManus; M Leung
Journal:  Sports Med       Date:  2000-04       Impact factor: 11.136

3.  Breathing pattern and ventilatory control in chronic tetraplegia.

Authors:  Ann M Spungen; William A Bauman; Marvin Lesser; F Dennis McCool
Journal:  Lung       Date:  2009-10-10       Impact factor: 2.584

4.  Impact of low filter resistances on subjective and physiological responses to filtering facepiece respirators.

Authors:  Raymond J Roberge; Jung-Hyun Kim; Jeffrey B Powell; Ronald E Shaffer; Caroline M Ylitalo; John M Sebastian
Journal:  PLoS One       Date:  2013-12-27       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.