Literature DB >> 4046867

Microvessel diameter changes during hemorrhagic shock in unanesthetized hamsters.

A Colantuoni, S Bertuglia, M Intaglietta.   

Abstract

The effects of hypovolemic shock on the time-dependent diameter changes of small arteries and arterioles were studied in the hamster skin fold window preparation. This experimental model permits the visualization of the microvasculature without the effects of acute surgery, anesthesia, and exposure. In these conditions, all the arterial microvessels showed vasomotion, while the venules and small veins, that were also studied, did not show rhythmic diameter changes. Hemorrhage was induced by the withdrawal of blood through a chronically implanted arterial catheter. The mean arterial blood pressure was reduced to 40 mm Hg in 20 min, and was maintained at this value for an additional 30-min period. Reinfusion of the withdrawn blood was made at 50 min. During the shock period, vasomotion disappeared in all arterial vessels. The small arteries and arterioles, A1 (70-100 micron, mean diameter), A2 (40-70 micron, md), and A3 (15-40 micron, md), contracted by 20 +/- 7, 33 +/- 10, and 34 +/- 11% of the control mean diameter, respectively. A4 terminal arterioles (less than 15 micron, md) dilated after the onset of bleeding; their rhythmic diameter changes subsequently stopped and their mean diameter increased by 75 +/- 7% of the original value. V1 small veins (150-200 micron, md) contracted during shock, while V2 (35-55 micron, md), V3 (25-35 micron, md), and V4 (15-25 micron, md) venous vessels did not show any significant change. Reinfusion of shed blood caused the reappearance of vasomotion; control vasomotion patterns recovered after reinfusion. Our results indicate that the microcirculatory responses to hypovolemic shock are dependent on the vessel type; this inhomogeneous reactivity may be due to the different responsiveness of microvessels to the mechanisms elicited by hemorrhage.

Entities:  

Mesh:

Year:  1985        PMID: 4046867     DOI: 10.1016/0026-2862(85)90045-7

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  6 in total

1.  Impairment of functional capillary density but not oxygen delivery in the hamster window chamber during severe experimental malaria.

Authors:  Judith Martini; Irene Gramaglia; Marcos Intaglietta; Henri C van der Heyde
Journal:  Am J Pathol       Date:  2007-02       Impact factor: 4.307

2.  Spontaneous oscillations in a model for active control of microvessel diameters.

Authors:  J C Arciero; T W Secomb
Journal:  Math Med Biol       Date:  2011-04-27       Impact factor: 1.854

3.  Precision real-time evaluation of bowel perfusion: accuracy of confocal endomicroscopy assessment of stoma in a controlled hemorrhagic shock model.

Authors:  Michele Diana; Eric Noll; Anne-Laure Charles; Pierre Diemunsch; Bernard Geny; Yu-Yin Liu; Francesco Marchegiani; Luigi Schiraldi; Vincent Agnus; Veronique Lindner; Lee Swanström; Bernard Dallemagne; Jacques Marescaux
Journal:  Surg Endosc       Date:  2016-06-20       Impact factor: 4.584

4.  On-chip evaluation of shear stress effect on cytotoxicity of mesoporous silica nanoparticles.

Authors:  Donghyuk Kim; Yu-Shen Lin; Christy L Haynes
Journal:  Anal Chem       Date:  2011-10-27       Impact factor: 6.986

5.  Variations of rhythmic diameter changes at the arterial microvascular bifurcations.

Authors:  A Colantuoni; S Bertuglia; M Intaglietta
Journal:  Pflugers Arch       Date:  1985-03       Impact factor: 3.657

6.  Systemic and microcirculatory responses to progressive hemorrhage.

Authors:  Arnaldo Dubin; Mario Omar Pozo; Gonzalo Ferrara; Gastón Murias; Enrique Martins; Carlos Canullán; Héctor Saul Canales; Vanina Siham Kanoore Edul; Elisa Estenssoro; Can Ince
Journal:  Intensive Care Med       Date:  2009-01-06       Impact factor: 17.440

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.