Nuclear medicine liver-function tests for pregnant women and children. 2. A new test method via urine using 15N-methacetin.

P Krumbiegel, K Hirschberg, H Faust, K Günther, G Schneider.   

Abstract

A simple, non-invasive, non-radioactive liver-function test is proposed. After an oral dose of 3 mg 15N-methacetin per kilogram body mass, the kinetics of 15N excretion via urine were characterized by the quotient of the amounts of 15N excreted in two successive urine samples (Q value). The stable nitrogen isotope 15N was found to be an excellent and easily detectable indicator of the sum of all methacetin metabolites present in urine. Alterations in the nature or ratio of methacetin metabolites due to liver diseases could not be found. From the investigation of 11 men, 3 pregnant women and 15 children, a clear difference was observed in Q values of healthy persons and patients suffering from liver-cell-activity diseases. The discriminating power of our new liver-function test is shown to be equivalent to that of the 14CO2 breath test.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4043116     DOI: 10.1007/bf00252133

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  Proceedings: Drug metabolism and quantitative liver function.

Authors:  P B Andreasen
Journal:  Arzneimittelforschung       Date:  1976

2.  Comparative metabolic studies of phenacetin and structurally-related compounds in the rat.

Authors:  G E Smith; L A Griffiths
Journal:  Xenobiotica       Date:  1976-04       Impact factor: 1.908

3.  Clearance of antipyrine-dependence of quantitative liver function.

Authors:  P B Andreasen; L Ranek; B E Statland; N Tygstrup
Journal:  Eur J Clin Invest       Date:  1974-04       Impact factor: 4.686

4.  Clinical diagnosis with the stable isotope 13C in CO2 breath tests: methodology and fundamental considerations.

Authors:  D A Schoeller; J F Schneider; N W Solomons; J B Watkins; P D Klein
Journal:  J Lab Clin Med       Date:  1977-09

5.  A liver-function test using 15N-labelled ammonium chloride.

Authors:  K Jung; K Hirschberg; H Faust; R Matkowitz
Journal:  Eur J Nucl Med       Date:  1985

6.  Nuclear medicine liver function tests for pregnant women and children. 1. Breath tests with 14C-methacetin and 13C-methacetin.

Authors:  P Krumbiegel; K Günther; H Faust; G Möbius; K Hirschberg; G Schneider
Journal:  Eur J Nucl Med       Date:  1985

7.  [Use of breath analysis in diagnosis of liver function (author's transl)].

Authors:  W F Caspary
Journal:  Z Gastroenterol       Date:  1978-03       Impact factor: 2.000

  7 in total
  3 in total

1.  A liver-function test using 15N-labelled ammonium chloride.

Authors:  K Jung; K Hirschberg; H Faust; R Matkowitz
Journal:  Eur J Nucl Med       Date:  1985

2.  Influence of intrauterine growth retardation on parameters of liver function in low birth weight infants.

Authors:  G Boehm; D M Müller; B Teichmann; P Krumbiegel
Journal:  Eur J Pediatr       Date:  1990-03       Impact factor: 3.183

3.  [15N]methacetin urine test: a method to study the development of hepatic detoxification capacity.

Authors:  P Krumbiegel; B Teichmann; G Boehm
Journal:  Eur J Pediatr       Date:  1990-03       Impact factor: 3.183

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.