Literature DB >> 4035558

Intraocular tamponade and surface tension.

E de Juan, B McCuen, J Tiedeman.   

Abstract

Surface tension is an important property of substances used as intraocular tamponades. The physical properties of currently available intraocular tamponades (gases, silicone oil and Healon) are compared with emphasis on surface tension. The gas/water interface surface tension is the greatest and therefore is the most effective in closing retinal breaks (70 erg/cm2). This is followed by silicone oil/water interface surface tension (50 erg/cm2). Healon is a 1% solution of water and therefore has no surface tension. Practical and theoretical considerations of various tamponades are described. Some properties of an ideal tamponade are suggested.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4035558     DOI: 10.1016/0039-6257(85)90088-8

Source DB:  PubMed          Journal:  Surv Ophthalmol        ISSN: 0039-6257            Impact factor:   6.048


  20 in total

1.  Perfluorocarbon-perfused vitrectomy: a new method for vitrectomy--a safety and feasibility study.

Authors:  Hugo Quiroz-Mercado; J Guerrero-Naranjo; R Agurto-Rivera; C Leizaola-Fernández; L Suárez-Tatá; S Murillo-López; G Reategui-Escalante; G García-Aguirre; J Fromow-Guerra
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-12-17       Impact factor: 3.117

2.  Vitreous replacement by gas as a therapeutic modality in bacterial endophthalmitis.

Authors:  A M Mansour; E Ferguson; H Lucia; M Rajashekhar; H Li; T Margo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

3.  Comment on "Vitrectomy with scleral buckling versus with inferior retinectomy in treating primary rhegmatogenous retinal detachment with PVR and inferior breaks".

Authors:  Upma Awasthi; Rohini Grover; Chetan Videkar; Abhishek Varshney
Journal:  Eye (Lond)       Date:  2018-12-18       Impact factor: 3.775

4.  High-frequency electric welding: a novel method for improved immediate chorioretinal adhesion in vitreoretinal surgery.

Authors:  Nicolay Umanets; Natalya V Pasyechnikova; Vladimir A Naumenko; Paul B Henrich
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-07-17       Impact factor: 3.117

5.  A microbubble of gas as an early indication of macular hole formation after vitrectomy surgery for retinal detachment repair.

Authors:  Alexander Melamud; Dionysios Koroulakis; Ferdinand Rodriguez-Agramonte
Journal:  Digit J Ophthalmol       Date:  2017-09-03

6.  Experimental retinal tolerance to very low viscosity silicone oil (100 cs) as a vitreous substitute compared to higher viscosity silicone oil (5000 cs).

Authors:  M Soheilian; G A Peyman; T Moritera; H Wafapoor
Journal:  Int Ophthalmol       Date:  1995       Impact factor: 2.031

7.  Contact angles of substances used for internal tamponade in retinal detachment surgery.

Authors:  I M Fawcett; R L Williams; D Wong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-07       Impact factor: 3.117

8.  Tamponade properties of double-filling with perfluorohexyloctane and silicone oil in a model eye chamber.

Authors:  Edward Herbert; Theodor Stappler; Carolina Wetterqvist; Rachel Williams; David Wong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-12-18       Impact factor: 3.117

9.  Vitrectomy and gas for inferior break retinal detachments: are the results comparable to vitrectomy, gas, and scleral buckle?

Authors:  L Wickham; M Connor; G W Aylward
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

10.  Inhibition of migration but stimulation of proliferation of human retinal pigment epithelial cells cultured with uniform vesicles of silicone oil.

Authors:  Li-Na Ma; Yan-Nian Hui; Yu-Sheng Wang; Le Zhang; Ji-Xian Ma
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-11-27       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.