Literature DB >> 4032861

Five-year clinical evaluation of the St. Jude Medical valve prosthesis in 136 patients.

K Koja, A Kusaba, I Yara, M Kina, T Uesato, Y Kuniyoshi, K Iha.   

Abstract

One hundred and thirty-six patients (June 1979, through May 1984) underwent mitral, aortic or double valve replacement and apico-aortic bypass with the St. Jude Medical (SJM) prosthesis, at Ryukyu University Hospital, Okinawa. Operative mortality for the entire group was 4.4 per cent. Late mortality from 1979-1984 was 6.1 per cent. There were no deaths related to mechanical failure. Warfarin anticoagulation was recommended for all patients. The incidence of thromboembolism was 0.76/100 patient years. Post operative catheterization studies in 21 patients one year after operation showed a satisfactory recovery of cardiac function. The SJM valve seems to be the satisfactory artificial valve in present use.

Entities:  

Mesh:

Year:  1985        PMID: 4032861     DOI: 10.1007/bf02469883

Source DB:  PubMed          Journal:  Jpn J Surg        ISSN: 0047-1909


  12 in total

1.  Entrapment of both leaflets of St. Jude Medical aortic valve prosthesis in a child.

Authors:  A Sharma; D C Johnson; T B Cartmill
Journal:  J Thorac Cardiovasc Surg       Date:  1983-09       Impact factor: 5.209

2.  Fatal thrombosis of an aortic St. Jude Medical valve despite "adequate" anticoagulation: anatomic and technical considerations.

Authors:  A L Moulton; R T Singleton; W F Oster; J Bosley; W Mergner
Journal:  J Thorac Cardiovasc Surg       Date:  1982-03       Impact factor: 5.209

3.  Worldwide experience with the St. Jude Medical valve prosthesis: clinical and hemodynamic results.

Authors:  C W Lillehei
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1982-04

4.  First clinical experience with a new all-pyrolytic carbon bileaflet heart valve prosthesis.

Authors:  F W Hehrlein; M Gottwik; G Fraedrich; J Mulch
Journal:  J Thorac Cardiovasc Surg       Date:  1980-04       Impact factor: 5.209

5.  Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus.

Authors:  D C Wortham; T B Tri; T E Bowen
Journal:  J Thorac Cardiovasc Surg       Date:  1981-04       Impact factor: 5.209

6.  Thrombosis of a St. Jude Medical tricuspid prosthesis. Case report.

Authors:  T E Bowen; T B Tri; D C Wortham
Journal:  J Thorac Cardiovasc Surg       Date:  1981-08       Impact factor: 5.209

7.  Cardiac valve prostheses in children without anticoagulation.

Authors:  H I Pass; R M Sade; F A Crawford; A R Hohn
Journal:  J Thorac Cardiovasc Surg       Date:  1984-06       Impact factor: 5.209

8.  Comparison of porcine valve xenografts with mechanical prostheses. A 7 1/2 year experience.

Authors:  L D Joyce; R M Nelson
Journal:  J Thorac Cardiovasc Surg       Date:  1984-07       Impact factor: 5.209

9.  Clinical and hemodynamic results with the St. Jude Medical cardiac valve prosthesis. A three-year experience.

Authors:  D M Nicoloff; R W Emery; K V Arom; W F Northrup; C R Jorgensen; Y Wang; W G Lindsay
Journal:  J Thorac Cardiovasc Surg       Date:  1981-11       Impact factor: 5.209

10.  Comparative method for actuarial analysis of cardiac valve replacements.

Authors:  E Bodnar; S Haberman; W H Wain
Journal:  Br Heart J       Date:  1979-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.