Literature DB >> 4031267

Comparison of high pulse repetition frequency and continuous wave Doppler echocardiography in the assessment of high flow velocity in patients with valvular stenosis and regurgitation.

W J Stewart, K A Galvin, L D Gillam, D E Guyer, A E Weyman.   

Abstract

Continuous wave Doppler echocardiography has proved useful in detecting and quantitating the high velocity flow disturbances that characterize many stenotic and regurgitant valvular lesions. Pulsed Doppler echocardiography, in contrast, is limited in its ability to quantitate the high velocities that are detected. Recently, new pulsed Doppler systems have been developed that employ high pulse repetition frequencies and can theoretically measure higher flow velocities than those measured by the standard pulsed Doppler systems. To determine the ability of high pulse repetition frequency Doppler echocardiography to accurately measure high velocity flow signals in comparison with the continuous wave method, 80 patients undergoing routine echocardiographic examination for the assessment of valvular heart disease were studied using both techniques. A total of 113 high velocity flow disturbances were detected in 68 patients. In 41 instances, the maximal velocities by the two methods were within 0.5 m/s of each other. In 68 of the 113 high velocity lesions, however, the high pulse repetition frequency technique underestimated the peak velocity found with continuous wave Doppler echocardiography by more than 0.5 m/s. Comparison of the peak velocities recorded by the two methods for the total group showed no significant correlation (r = 0.04, p = NS). Comparison of the difference in peak velocities obtained by the two techniques with the maximal continuous wave velocity (n = 94, r = 0.70, slope = 0.71) suggested that the underestimation becomes greater as the peak velocity increases. Fifteen of the study patients with aortic stenosis subsequently underwent catheterization.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1985        PMID: 4031267     DOI: 10.1016/s0735-1097(85)80114-5

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

Review 1.  Assessment of cardiac hemodynamics and valvular function by Doppler echocardiography.

Authors:  D C Wallerson; J Dubin; R B Devereux
Journal:  Bull N Y Acad Med       Date:  1987-10

Review 2.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

3.  Tricuspid valve replacement with the St. Jude Medical valve.

Authors:  S Aoyagi; Y Nishi; T Kawara; A Oryoji; H Hara; K Kosuga; K Ohishi
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.