Literature DB >> 4028767

Frequency of wedge pressure errors in the ICU.

A H Morris, R H Chapman, R M Gardner.   

Abstract

Using 94 flow-directed pulmonary artery catheters in 53 ICU patients, we obtained prospectively 282 pulmonary artery wedge pressure (WP) measurements from 286 attempts. After catheter manipulation, 96% of these WP measurements were ultimately free of technical problems, and 84% were confirmed by aspiration of pulmonary capillary blood from the wedge position. The 95% confidence interval for repeated measurements of WP in stable ICU patients was 4 mm Hg. The WP measurement error was defined as the difference between unconfirmed and confirmed WP pairs obtained from stable patients. The probability of encountering a WP measurement error of at least 4 mm Hg was 33% for the 93 WP measurements with technical problems, 5% for the 189 WP measurements without technical problems, and 14% for the entire set of 286 WP measurement attempts. Quality control procedures, including dynamic response testing, easily identified most errors.

Entities:  

Mesh:

Year:  1985        PMID: 4028767     DOI: 10.1097/00003246-198509000-00002

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  5 in total

1.  Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler.

Authors:  Margareta Roeck; Stephan M Jakob; Thomas Boehlen; Lukas Brander; Rafael Knuesel; Jukka Takala
Journal:  Intensive Care Med       Date:  2003-04-09       Impact factor: 17.440

2.  Effect of balloon inflation volume on pulmonary artery occlusion pressure in patients with and without pulmonary hypertension.

Authors:  Adriano R Tonelli; Kamal K Mubarak; Ning Li; Robin Carrie; Hassan Alnuaimat
Journal:  Chest       Date:  2010-07-01       Impact factor: 9.410

3.  Limitations of medical research and evidence at the patient-clinician encounter scale.

Authors:  Alan H Morris; John P A Ioannidis
Journal:  Chest       Date:  2013-04       Impact factor: 9.410

Review 4.  Haemodynamic monitoring. Problems, pitfalls and practical solutions.

Authors:  L L Bossaert; H E Demey; R De Jongh; L Heytens
Journal:  Drugs       Date:  1991-06       Impact factor: 9.546

5.  The impact of a pulmonary-artery-catheter-based protocol on fluid and catecholamine administration in early sepsis.

Authors:  Carina Bethlehem; Frouwke M Groenwold; Hanneke Buter; W Peter Kingma; Michael A Kuiper; Fellery de Lange; Paul Elbers; Henk Groen; Eric N van Roon; E Christiaan Boerma
Journal:  Crit Care Res Pract       Date:  2012-02-21
  5 in total