Literature DB >> 4028757

Real-time analysis of the change in arterial oxygen tension during endotracheal suction with a fiberoptic bronchoscope.

T Arai, Y Hatano, K Komatsu, T Takada, C Miyake, T Harioka, K Reshad.   

Abstract

An intra-arterial Clark-type polarographic oxygen electrode was used with a fiberoptic bronchoscope for real-time analysis of the PO2 change during 1 min of suction in patients spontaneously breathing oxygen. There was a strong correlation between values obtained from the intra-arterial electrode (PiO2) and those from blood samples (PaO2), before and at the end of suction; the PiO2/PaO2 ratio was close to one. Continuous PiO2 recordings during suction without supplemental oxygen showed little change in the early period of suction, followed by a steep drop continuing even after suction. This drop in PiO2 was partially attenuated by providing oxygen with high-frequency jet ventilation and was almost completely attenuated by the use of a suction adaptor. Changes in the inspired oxygen concentration indicated the importance of keeping this variable constant during suction to prevent hypoxemia.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4028757     DOI: 10.1097/00003246-198510000-00017

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  4 in total

1.  Endotracheal suctioning: from principles to practice.

Authors:  Brenda M Morrow; Merle J Futter; Andrew C Argent
Journal:  Intensive Care Med       Date:  2004-03-18       Impact factor: 17.440

2.  Diagnostic bronchoalveolar lavage in patients with pneumonia produces sepsis-like systemic effects.

Authors:  J Pugin; P M Suter
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

3.  Comparison of nonbronchoscopic bronchoalveolar lavage to open lung biopsy for the bacteriologic diagnosis of pulmonary infections in mechanically ventilated patients.

Authors:  P Gaussorgues; D Piperno; P Bachmann; F Boyer; G Jean; M Gérard; P Léger; D Robert
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

4.  Effects of diagnostic procedures during fiberoptic bronchoscopy on heart rate, blood pressure, and blood gases.

Authors:  H W Breuer; S Charchut; H Worth
Journal:  Klin Wochenschr       Date:  1989-05-15