Literature DB >> 4028367

Improved right ventricular function after intra-atrial repair of transposition of the great arteries.

T P Graham, J Burger, H W Bender, J W Hammon, R J Boucek, S Appleton.   

Abstract

Current interest in the arterial switch operation for simple transposition of the great arteries (TGA) has led us to evaluate our latest patients who have undergone intra-atrial repair. Right ventricular function and overall results were compared in 32 patients who had undergone the Senning procedure between 1978 and 1983 and 26 patients who had undergone Mustard repair between 1971 and 1978). Deep hypothermia and circulatory arrest were used in all Senning operations and in 18 of 26 Mustard procedures. Cardiac catheterization was performed an average of 1 year after surgery in all patients. Postoperative right ventricular ejection fraction (EF) was below normal (less than 0.49) in 16 of 32 patients who underwent the Senning procedure and averaged 0.48 +/- 0.09. In the patients in this group with abnormal right ventricular EFs after repair there was a fall in the value after surgery (0.51 to 0.40, p less than .001), while in those with normal right ventricular EFs after repair there was no change (0.57 to 0.55, NS). All 32 patients who underwent the Senning procedure were compared with 26 patients who underwent the Mustard operation (13 treated between 1971 and 1974 and 13 treated between 1975 and 1978). An older age at surgery (12 +/- 7 vs 6 +/- 8 months, p less than .006) and a lower preoperative right ventricular EF (0.46 +/- 0.09 vs 0.54 +/- 0.08, p less than .007) characterized the Mustard vs the Senning group.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1985        PMID: 4028367

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  Historical note: letter regarding heart surgery in England.

Authors:  W Somerville
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

2.  Limited Ventricular Preload is the Main Reason for Reduced Stress Reserve After Atrial Baffle Repair.

Authors:  Andreas Eicken; Julia Michel; Alfred Hager; Daniel Tanase; Harald Kaemmerer; Julie Cleuziou; John Hess; Peter Ewert
Journal:  Pediatr Cardiol       Date:  2016-11-24       Impact factor: 1.655

3.  Long-term ventricular performance after intra-atrial correction of transposition: left ventricular filling is the major limitation.

Authors:  O Reich; M Vorísková; C Ruth; M Krejcír; J Marek; J Skovránek; B Hucín; M Samánek
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

4.  Results with the Mustard operation in simple transposition of the great arteries 1963-1985.

Authors:  G A Trusler; W G Williams; K F Duncan; P S Hesslein; L N Benson; R M Freedom; T Izukawa; P M Olley
Journal:  Ann Surg       Date:  1987-09       Impact factor: 12.969

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.