Literature DB >> 4028349

Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium.

J M Lee, D R Boughner.   

Abstract

Whereas most experiments on the mechanical function of the pericardium have been performed on dogs, very little is known about the applicability of those data to humans. To examine the tensile viscoelastic properties of fresh human pericardium, we have used the methods from our previous study of canine pericardium. Although the mechanical responses of canine and human pericardium were qualitatively similar, human pericardium displayed a significantly greater viscous character. Human pericardium was 7.3 times thicker than canine pericardium, but was more extensible in stress-strain tests, with lower stiffness at a given strain. The static (elastic) stiffness of human pericardium seems identical to that of canine pericardium; lower stiffness per unit thickness of the human tissue at predicted physiological stresses was almost exactly compensated by the greater wall thickness. This effect was also seen in data on fracture strength and stiffness. However, human pericardium displayed greater viscous responses than the canine tissue. This was seen in doubled cyclic hysteresis losses, and greater stress relaxation and creep. Our results suggest that experiments on the viscoelastic properties of canine pericardium may not be directly applicable to humans, especially where dynamic mechanical properties are most important: i.e., in studies of ventricular function and the time-course of pericardial effusions.

Entities:  

Mesh:

Year:  1985        PMID: 4028349     DOI: 10.1161/01.res.57.3.475

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  11 in total

1.  Boundary conditions during biaxial testing of planar connective tissues. Part 1: dynamic behavior.

Authors:  Stephen D Waldman; J Michael Lee
Journal:  J Mater Sci Mater Med       Date:  2002-10       Impact factor: 3.896

2.  Mechanical and optical anisotropy of bovine pericardium.

Authors:  P Zioupos; J C Barbenel; J Fisher
Journal:  Med Biol Eng Comput       Date:  1992-01       Impact factor: 2.602

3.  Time-dependent biaxial mechanical behavior of the aortic heart valve leaflet.

Authors:  John A Stella; Jun Liao; Michael S Sacks
Journal:  J Biomech       Date:  2007-06-13       Impact factor: 2.712

4.  Personalized intervention cardiology with transcatheter aortic valve replacement made possible with a non-invasive monitoring and diagnostic framework.

Authors:  Seyedvahid Khodaei; Alison Henstock; Reza Sadeghi; Stephanie Sellers; Philipp Blanke; Jonathon Leipsic; Ali Emadi; Zahra Keshavarz-Motamed
Journal:  Sci Rep       Date:  2021-05-25       Impact factor: 4.379

Review 5.  Physiology of pericardial fluid production and drainage.

Authors:  Konstantinos Vogiatzidis; Sotirios G Zarogiannis; Isaac Aidonidis; Evgeniy I Solenov; Paschalis-Adam Molyvdas; Konstantinos I Gourgoulianis; Chrissi Hatzoglou
Journal:  Front Physiol       Date:  2015-03-18       Impact factor: 4.566

6.  Hydraulic forces contribute to left ventricular diastolic filling.

Authors:  Elira Maksuti; Marcus Carlsson; Håkan Arheden; Sándor J Kovács; Michael Broomé; Martin Ugander
Journal:  Sci Rep       Date:  2017-03-03       Impact factor: 4.379

7.  Multilayer myocardial strain improves the diagnosis of heart failure with preserved ejection fraction.

Authors:  Radu Tanacli; Djawid Hashemi; Marthe Neye; Laura Astrid Motzkus; Moritz Blum; Elvis Tahirovic; Aleksandar Dordevic; Robin Kraft; Seyedeh Mahsa Zamani; Burkert Pieske; Hans-Dirk Düngen; Sebastian Kelle
Journal:  ESC Heart Fail       Date:  2020-06-21

8.  Mechanical compliance and immunological compatibility of fixative-free decellularized/cryopreserved human pericardium.

Authors:  Maria Cristina Vinci; Giulio Tessitore; Laura Castiglioni; Francesca Prandi; Monica Soncini; Rosaria Santoro; Filippo Consolo; Francesca Colazzo; Barbara Micheli; Luigi Sironi; Gianluca Polvani; Maurizio Pesce
Journal:  PLoS One       Date:  2013-05-21       Impact factor: 3.240

9.  Biomaterial characterization of off-the-shelf decellularized porcine pericardial tissue for use in prosthetic valvular applications.

Authors:  Joshua A Choe; Soumen Jana; Brandon J Tefft; Ryan S Hennessy; Jason Go; David Morse; Amir Lerman; Melissa D Young
Journal:  J Tissue Eng Regen Med       Date:  2018-05-30       Impact factor: 3.963

Review 10.  Design and applications of biodegradable polyester tissue scaffolds based on endogenous monomers found in human metabolism.

Authors:  Devin G Barrett; Muhammad N Yousaf
Journal:  Molecules       Date:  2009-10-12       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.