Literature DB >> 4022493

Accurate gestational dating.

W J Ott.   

Abstract

Gestational age by four ultrasonic parameters (biparietal diameter, head circumference, abdominal circumference, and femur length) was calculated for 210 normal obstetric patients divided into four gestational age groups based on time of first ultrasound examination. Accuracy of the calculations was determined by comparison of each technique and a simple arithmetic average of the four techniques to the gestational age calculated from the Dubowitz examination of the neonate after delivery. The analysis indicated that each ultrasonic technique has certain advantages and disadvantages, but that the simple arithmetic average of the four techniques had the lowest systematic and random error.

Entities:  

Mesh:

Year:  1985        PMID: 4022493

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  7 in total

1.  Gestational age reporting and preterm delivery.

Authors:  G R Alexander; M E Tompkins; D A Cornely
Journal:  Public Health Rep       Date:  1990 May-Jun       Impact factor: 2.792

2.  Variations in the reporting of gestational age at induced termination of pregnancy.

Authors:  D J Petersen; G R Alexander; E Powell-Griner; M E Tompkins
Journal:  Am J Public Health       Date:  1989-05       Impact factor: 9.308

3.  Discordance between LMP-based and clinically estimated gestational age: implications for research, programs, and policy.

Authors:  G R Alexander; M E Tompkins; D J Petersen; T C Hulsey; J Mor
Journal:  Public Health Rep       Date:  1995 Jul-Aug       Impact factor: 2.792

4.  Fetal growth in muskoxen determined by transabdominal ultrasonography.

Authors:  J W Pharr; J E Rowell; P F Flood
Journal:  Can J Vet Res       Date:  1994-07       Impact factor: 1.310

5.  The reliability of hand-written and computerised records of birth data collected at Baragwanath hospital in Soweto.

Authors:  G T Ellison; L M Richter; T de Wet; H E Harris; R D Griesel; J A McIntyre
Journal:  Curationis       Date:  1997-03

6.  Improving the accuracy of birth notification data: lessons from the Birth to Ten study.

Authors:  Gth Ellison; Lm Richter; T de Wet; He Harris; Rd Griesel; Ja McIntyre
Journal:  South Afr J Epidemiol Infect       Date:  1997

Review 7.  Second and third trimester estimation of gestational age using ultrasound or maternal symphysis-fundal height measurements: A systematic review.

Authors:  Alice Self; Lama Daher; Michael Schlussel; Nia Roberts; Christos Ioannou; Aris T Papageorghiou
Journal:  BJOG       Date:  2022-03-10       Impact factor: 7.331

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.