Literature DB >> 4017443

Heart sound propagation in the human thorax.

F Meno, P S Reddy, L Bernardi.   

Abstract

Simultaneous quantitative recordings of pressure in the aorta near a prosthetic valve and at two locations externally on the chest provide data on certain aspects of sound propagation in the human thorax. On the basis of the different speeds of propagation, it is possible to distinguish between the longitudinal and transverse vibrations contributing to the external phonocardiographic signal. Digital signal processing was employed to derive transfer functions, correlations and power spectra.

Entities:  

Mesh:

Year:  1985        PMID: 4017443     DOI: 10.1088/0143-0815/6/2/003

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  7 in total

1.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Part 3. Effects of altering heart rate and P-R interval.

Authors:  L G Durand; Y E Langlois; T Lanthier; R Chiarella; P Coppens; S Carioto; S Bertrand-Bradley
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

2.  Interaction between the aortic valve leaflets and a Millar dual-micromanometer catheter during recording of the aortic component of the second heart sound in dogs.

Authors:  L G Durand; Y E Langlois; T Lanthier; R Chiarella; P Coppens; S Carioto; S Bertrand-Bradley
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

3.  Heart sounds analysis via esophageal stethoscope system in beagles.

Authors:  Sang Hi Park; Young Duck Shin; Jin Ho Bae; Eun Jung Kwon; Tae-Soo Lee; Ji-Yun Shin; Yeong-Cheol Kim; Gyeong-Deuk Min; Myoung hwan Kim
Journal:  J Clin Monit Comput       Date:  2013-03-26       Impact factor: 2.502

4.  Spectral analysis and acoustic transmission of mitral and aortic valve closure sounds in dogs. Part 1. Modelling the heart/thorax acoustic system.

Authors:  L G Durand; Y E Langlois; T Lanthier; R Chiarella; P Coppens; S Carioto; S Bertrand-Bradley
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

5.  Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.

Authors:  A Moritz; U Steinseifer; G Kobinia; K Neuwirth-Riedl; H Wolters; H Reul; E Wolner
Journal:  Br Heart J       Date:  1992-06

6.  Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission.

Authors:  Kyoung Hoon Lim; Young Duck Shin; Sang Hi Park; Jin Ho Bae; Hong Jae Lee; Seon Jung Kim; Ji Yun Shin; Young Jin Choi
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

7.  The correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia.

Authors:  Young Duck Shin; Kyoung Hoon Yim; Sang Hi Park; Yong Wook Jeon; Jin Ho Bae; Tae Soo Lee; Myoung Hwan Kim; Young Jin Choi
Journal:  Pak J Med Sci       Date:  2014-03       Impact factor: 1.088

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.