Literature DB >> 401460

Comparative study of superficial whole-body radiotherapeutic techniques using a 4-MeV nonangulated electron beam.

P J Tetenes, P N Goodwin.   

Abstract

Various whole-body, multiple-field, electron-beam therapy techniques are analyzed. Accelerator characteristics, various dosimetric techniques, and experimental setup are described. A flattening filter was constructed which produced an uncollimated electron-beam profile (4 MeV) with a uniformity of +/- 8% across a 200-cm diameter area at 7 m from the source. Irradiation techniques include 2-, 4-, 6-, and 8-field therapy and rotation. Conclusive evidence is presented to support adoption of either the 8-field technique or rotation as the methods of choice for superficial whole-body treatments.

Mesh:

Year:  1977        PMID: 401460     DOI: 10.1148/122.1.219

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  2 in total

1.  Total skin electron beam therapy using an inclinable couch on motorized table and a compensating filter.

Authors:  H Fuse; K Suzuki; K Shida; Y Mori; H Takahashi; D Kobayashi; M Seki; T Isobe; T Okumura; T Sakae; H Sakurai
Journal:  Rev Sci Instrum       Date:  2014-06       Impact factor: 1.523

2.  Total skin electron beam therapy rationalization and utility of in vivo dosimetry in a high-volume centre.

Authors:  Sarah Misson-Yates; Marium Naeem; Isabel Palmer; Eleanor Holden; Owen Hedley; Mark McGovern; Stephen Morris; Anthony G Greener
Journal:  BJR Open       Date:  2019-07-20
  2 in total