Transcutaneous bilirubinometry: a comparison of old and new methods.

R E Schumacher, J M Thornbery, G R Gutcher.   

Abstract

Two devices for hyperbilirubinemia screening were compared: the Minolta jaundice meter and the 30-year-old Ingram icterometer. Serum bilirubin values were obtained from a population of 106 healthy newborns with jaundice. A linear correlation existed between serum bilirubin values and the readings on the jaundice meter (y = 0.91x + 9.25, r = .74, standard error of the estimate (sy X x) = 2.02). The device classified hyperbilirubinemia with a sensitivity of 94% and specificity of 77.5%. A linear correlation existed between serum bilirubin values and the readings on the icterometer (y = 0.17x + 1.74, r = .63, sy X x = 0.38). The device classified hyperbilirubinemia with a sensitivity of 82% and specificity of 74%. The population studied was preselected for the presence of jaundice and each data point obtained was from a different patient. As a result, the correlation coefficient obtained from the jaundice meter is lower than others reported, but is more representative of the value that should be obtained under routine nursery situations. Both devices perform well as screening devices; at optimal cutpoints, no statistically significant difference in their efficacy can be demonstrated. Despite the availability of more complex and expensive devices, the icterometer continues to serve as a cost-effective screening device for hyperbilirubinemia.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4011341

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  5 in total

1.  Estimation of bilirubin using BiliChektrade mark, a transcutaneous bilirubin measurement device: Effects of gestational age and use of phototherapy.

Authors:  Ka Jangaard; H Curtis; Rb Goldbloom
Journal:  Paediatr Child Health       Date:  2006-02       Impact factor: 2.253

2.  Can transcutaneous bilirubinometry reduce the need for blood tests in jaundiced full term babies?

Authors:  L Briscoe; S Clark; C W Yoxall
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-05       Impact factor: 5.747

3.  A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields.

Authors:  C Mae Wong; P J E van Dijk; I A Laing
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-09       Impact factor: 5.747

Review 4.  Screening methods for neonatal hyperbilirubinemia: benefits, limitations, requirements, and novel developments.

Authors:  Christian V Hulzebos; Libor Vitek; Carlos D Coda Zabetta; Aleš Dvořák; Paul Schenk; Eline A E van der Hagen; Christa Cobbaert; Claudio Tiribelli
Journal:  Pediatr Res       Date:  2021-05-03       Impact factor: 3.756

5.  Maternal detection of neonatal jaundice during birth hospitalization using a novel two-color icterometer.

Authors:  Bolajoko O Olusanya; Tina M Slusher; Donald O Imosemi; Abieyuwa A Emokpae
Journal:  PLoS One       Date:  2017-08-24       Impact factor: 3.240