Current electrosurgical practice: hazards.

J Pearce.   

Abstract

The beneficial aspects of electrosurgical cutting and coagulating techniques are nearly too numerous to list. The major contribution and electrosurgery has been to drastically reduce both blood loss and operative time resulting in reduced morbidity and mortality. There are, as well, procedures which would not be possible without electrosurgery. Nonetheless, as a source of high energy in the operating theatre, there are hazards attendant to the use of electrosurgery. Moreover, since high frequency signals are involved, the nature of the machine-patient interactions creating a potentially hazardous situation many not be easily identifiable. The significant hazards of electrosurgery in use are: explosions of combustible mixtures including anaesthesia gas and bowel gas; interference with instruments and pacemakers; stimulation of excitable tissues which on occasion has apparently caused ventricular fibrillation; and accidental radio frequency burns. Though the rate of incidents is low--in terms of the number per 100 000 procedures--individual accidents tend to be fairly catastrophic and traumatic to both the patient and surgical team. Frequently, litigation results from these accidents. Though the hazards cannot be eliminated, the probability of an incident can be minimized by careful technique.

Entities:  

Mesh:

Year:  1985        PMID: 4009682     DOI: 10.3109/03091908509018138

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  5 in total

1.  Evaluation of electrosurgical interference to low-power spread-spectrum local area net transceivers.

Authors:  G L Gibby; W K Schwab; W C Miller
Journal:  J Clin Monit       Date:  1997-11

2.  Cardiac arrest from the use of diathermy during total hip arthroplasty in a patient with an external pacemaker.

Authors:  A J Andrade; M L Grover
Journal:  Ann R Coll Surg Engl       Date:  1997-01       Impact factor: 1.891

3.  Pain sensation and neuromuscular stimulation during argon plasma coagulation in gastrointestinal endoscopy.

Authors:  A Eickhoff; D Hartmann; J C Eickhoff; J F Riemann; M D Enderle
Journal:  Surg Endosc       Date:  2007-12-11       Impact factor: 4.584

4.  Factors predicts skin ulcer following coronary artery bypass.

Authors:  F Sabzi; R Faraji
Journal:  J Med Life       Date:  2014

5.  Case report: full-thickness forehead burn over indwelling titanium hardware resulting from an aberrant intraoperative electrocautery circuit.

Authors:  Gerhard S Mundinger; Shai M Rozen; Benjamin Carson; Robert S Greenberg; Richard J Redett
Journal:  Eplasty       Date:  2007-11-20