Lack of alerting reactions to intermittent cuff inflations during noninvasive blood pressure monitoring.

G Parati, G Pomidossi, R Casadei, G Mancia.   

Abstract

Intermittent noninvasive blood pressure monitoring is becoming increasingly popular because of the belief that a daytime blood pressure profile can provide a better clinical evaluation of hypertension than that provided by casual blood pressure measurements. This approach has potential limitations, however, one of which is that the cuff inflations permitting blood pressure to be repeatedly measured may induce an alerting reaction and a pressor response in the patients and lead to an overestimation of their daytime blood pressure. Blood pressure in 22 subjects was invasively recorded for 24 hours by the Oxford method. During the day of the recording blood pressure was also measured by a noninvasive device (Vita-Stat 901), which had its cuff applied to the opposite arm from which the intra-arterial signal was derived. For 2 hours the device provided automatic cuff inflations at 10-minutes intervals. For another 2 hours it was programmed to provide cuff inflations only following patients' commands, also at 10-minute intervals. Analysis of the intra-arterial blood pressure trace during the periods preceding and following the automatically or semiautomatically induced cuff inflations showed that these procedures caused no increment in systolic and diastolic blood pressure. This finding applied not only to the mean data but also to each individual measurement considered separately, including the initial one. Our results indicate that automatic and semiautomatic blood pressure monitorings do not induce an alarm reaction and a blood pressure rise and thus do not overestimate daytime blood pressure values.

Entities:  

Mesh:

Year:  1985        PMID: 4007993     DOI: 10.1161/01.hyp.7.4.597

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  14 in total

Review 1.  Hypertension.

Authors:  G W Ching; D G Beevers
Journal:  Postgrad Med J       Date:  1991-03       Impact factor: 2.401

2.  Blood pressure responses to stress: Relation to left ventricular structure and function.

Authors:  A L Hinderliter; K C Light; S S Girdler; P W Willis; A Sherwood
Journal:  Ann Behav Med       Date:  1996-03

Review 3.  The Un-Observed Automated Office Blood Pressure Measurement Technique Used in the SPRINT Study Points to a Standard Target Office Systolic Blood Pressure <140 mmHg.

Authors:  Sverre E Kjeldsen; Giuseppe Mancia
Journal:  Curr Hypertens Rep       Date:  2017-01       Impact factor: 5.369

4.  The Impact of Measurement Methods on Office Blood Pressure and Management of Hypertension in General Practice.

Authors:  Julia Höller; Linda Elizabeth Villagomez Fuentes; Klaus Matthias; Reinhold Kreutz
Journal:  High Blood Press Cardiovasc Prev       Date:  2019-11-09

Review 5.  Twenty-four-hour ambulatory blood pressure monitoring in hypertension: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2012-05-01

6.  Statistical evaluation of circadian blood pressure rhythm during isradipine long-term therapy.

Authors:  F Veglio; F Rabbia; R Melchio; L Chiandussi
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

Review 7.  Principles and techniques of blood pressure measurement.

Authors:  Gbenga Ogedegbe; Thomas Pickering
Journal:  Cardiol Clin       Date:  2010-11       Impact factor: 2.213

8.  Prevalence and reproducibility of differences between home and ambulatory blood pressure and their relation with hypertensive organ damage.

Authors:  K Gazzola; M Cammenga; N V van der Hoeven; G A van Montfrans; B J H van den Born
Journal:  J Hum Hypertens       Date:  2017-04-06       Impact factor: 3.012

9.  Captopril plus hydrochlorothiazide once daily normalizes 24 h blood pressure in patients with essential hypertension.

Authors:  J L Meijer; H G Ardesch; J C Van Rooijen; J H De Bruijn
Journal:  Br J Clin Pharmacol       Date:  1987       Impact factor: 4.335

10.  Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

Authors:  Gianfranco Parati; Stefano Omboni; Paolo Palatini; Damiano Rizzoni; Grzegorz Bilo; Mariaconsuelo Valentini; Enrico Agabiti Rosei; Giuseppe Mancia
Journal:  High Blood Press Cardiovasc Prev       Date:  2013-01-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.