Literature DB >> 4006467

Immediate post-placental IUD insertion: the expulsion problem.

M Thiery, H Van Kets, H Van der Pas.   

Abstract

This paper reports an evaluation of immediate post-placental insertion of a non-copper (Lippes Loop D) and several copper-bearing IUD models (TCu200, TCu220C, MLCu375, MLCu250, Nova T-PP, DimélysR). Based on the analysis of a total of 2,646 insertions and 55,794 woman-months of experience, we conclude that placement of an IUD within ten minutes of delivery of the placenta is a valuable alternative to interval insertion, because this method is safe and effective. Effectiveness was significantly lower for the Lippes Loop D than for the T- and ML-IUD models tested, the latter showing roughly comparable pertinent event rates. Pertinent event rates for copper IUDs were influenced by the skill of the operator; age of the recipient only had a significant effect on effectiveness, whereas parity had no significant effect on pertinent event rates. The single and still unsolved problem associated with immediate postpartum insertion is the greater likelihood of expulsion compared with interval insertion, and this hazard is significantly much greater for the Loop than for the copper-bearing devices assessed. The evolution of the expulsion rates shows a constant time-relationship. This pattern makes it obvious why follow-up of recipients, at least during the first trimester following insertion, is mandatory if immediate post-placental IUD insertion is to be optimally effective.

Entities:  

Mesh:

Year:  1985        PMID: 4006467     DOI: 10.1016/0010-7824(85)90002-2

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  4 in total

1.  A randomized trial of the intrauterine contraceptive device vs hormonal contraception in women who are infected with the human immunodeficiency virus.

Authors:  Elizabeth M Stringer; Christine Kaseba; Jens Levy; Moses Sinkala; Robert L Goldenberg; Benjamin H Chi; Inutu Matongo; Sten H Vermund; Mulindi Mwanahamuntu; Jeffrey S A Stringer
Journal:  Am J Obstet Gynecol       Date:  2007-08       Impact factor: 8.661

2.  Post placental insertion of intrauterine contraceptive device.

Authors:  Vanita Suri
Journal:  Indian J Med Res       Date:  2012-09       Impact factor: 2.375

3.  Provision of immediate postpartum intrauterine contraception after vaginal birth within a public maternity setting: Health services research evaluation.

Authors:  Michelle Cooper; Kevin McGeechan; Anna Glasier; Shiona Coutts; Frances McGuire; Jeni Harden; Nicola Boydell; Sharon T Cameron
Journal:  Acta Obstet Gynecol Scand       Date:  2019-12-29       Impact factor: 3.636

4.  Considerations on a new, frameless copper-releasing intrauterine system for intracesarean insertion and its future clinical significance: A review.

Authors:  Hazal Kutlucan; Recep Onur Karabacak; Dirk Wildemeersch
Journal:  J Turk Ger Gynecol Assoc       Date:  2020-06-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.