Literature DB >> 4000078

Investigation of basic imaging properties in digital radiography. 4. Effect of unsharp masking on the detectability of simple patterns.

L N Loo, K Doi, C E Metz.   

Abstract

The signal-to-noise ratios (SNRs) of simple radiologic patterns processed by the unsharp-masking technique were calculated on the basis of a statistical decision theory model that includes both the observer's visual transfer function and a noise component internal to his eye-brain system. For a variety of processing parameters, the contrast-detail diagrams predicted from this SNR agreed qualitatively with experimental results obtained in observer performance studies. Unsharp masking with a large mask and a large weighting factor improved the detection of square objects to a level comparable with that achieved by the overall contrast enhancement technique using a factor of 4. However, unsharp masking with a small mask and a large weighting factor can substantially degrade the detectability of these objects. The potential practical utility of the unsharp-masking technique is discussed.

Entities:  

Mesh:

Year:  1985        PMID: 4000078     DOI: 10.1118/1.595775

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Enhancement of chest images by automatic adaptive spatial filtering.

Authors:  M Souto; J Correa; P G Tahoces; D Tucker; K S Malagari; J J Vidal; R G Fraser
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

Review 2.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

3.  Data compression of x-ray cardio-angiographic image series.

Authors:  M Breeuwer; R Heusdens; R K Gunnewiek; P Zwart; H P Haas
Journal:  Int J Card Imaging       Date:  1995

4.  Image optimization in a computed-radiography/photostimulable-phosphor system.

Authors:  R H Sherrier; H G Chotas; G A Johnson; C Chiles; C E Ravin
Journal:  J Digit Imaging       Date:  1989-11       Impact factor: 4.056

5.  Gastrointestinal examinations with a 2,048- x 2,048-pixel image intensifier television digital radiography system.

Authors:  Y Baba; M Takahashi; T Tsuchigami; Y Higashida
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

6.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability.

Authors:  C K Abbey; H H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-03       Impact factor: 2.129

Review 7.  An engineering view on megatrends in radiology: digitization to quantitative tools of medicine.

Authors:  Namkug Kim; Jaesoon Choi; Jaeyoun Yi; Seungwook Choi; Seyoun Park; Yongjun Chang; Joon Beom Seo
Journal:  Korean J Radiol       Date:  2013-02-22       Impact factor: 3.500

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.