Literature DB >> 3999707

A circle of Willis simulation using distensible vessels and pulsatile flow.

R H Kufahl, M E Clark.   

Abstract

The development of a one-dimensional numerical (finite-difference) model of the arterial network surrounding the circle of Willis is described based on the full Navier-Stokes and conservation of mass equations generalized for distensible vessels. The present model assumes an elastic wall defined by a logarithmic pressure-area relation obtained from the literature. The viscous term in the momentum equation is evaluated using the slope of a Karman-Pohlhausen velocity profile at the vessel boundary. The afferent vessels (two carotids and two vertebrals) are forced with a canine physiologic pressure signature corresponding to an aortic site. The network associated with each main efferent artery of the circle is represented by a single vessel containing an appropriate amount of resistance so that the mean flow through the system is distributed in accordance with the weight of brain irrigated by each vessel as determined from a steady flow model of the same network. This resistance is placed a quarter wave-length downstream from the heart to insure proper reflection from the terminations, where the quarter wavelength is determined using the frequency corresponding to the first minimum on an input impedance-frequency diagram obtained at the heart. Computer results are given as time histories of pressure and flow at any model nodal point starting from initial conditions of null flow and constant pressure throughout the model. Variations in these pressure and flow distributions caused by the introduction of pathologic situations into the model illustrate the efficacy of the simulation and of the circle in equalizing and redistributing flows in abnormal situations.

Entities:  

Mesh:

Year:  1985        PMID: 3999707     DOI: 10.1115/1.3138531

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  BLOOD FLOW IN THE CIRCLE OF WILLIS: MODELING AND CALIBRATION.

Authors:  Kristen Devault; Pierre A Gremaud; Vera Novak; Mette S Olufsen; Guillaume Vernières; Peng Zhao
Journal:  Multiscale Model Simul       Date:  2008-01-27       Impact factor: 1.930

2.  Stereolithographic vascular replicas from CT scans: choosing treatment strategies, teaching, and research from live patient scan data.

Authors:  Kimberly Knox; Charles W Kerber; Soren A Singel; Michael J Bailey; Steven G Imbesi
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

Review 3.  Generic and patient-specific models of the arterial tree.

Authors:  Philippe Reymond; Orestis Vardoulis; Nikos Stergiopulos
Journal:  J Clin Monit Comput       Date:  2012-07-29       Impact factor: 2.502

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.