Literature DB >> 399798

Endothelial cell density determined by specular microscopy and scanning electron microscopy.

P S Binder, P Akers, E Y Zavala.   

Abstract

Human eyes were photographed with a specular microscope and later examined wit a scanning electron microscope. Corneas from patients undergoing corneal transplantation in whom we were able to obtain preoperative specular micrographs were similarly analyzed. An attempt was made to correlate the counts obtained with both microscopic techniques by determining the amount of shrinkage the cornea undergoes while being processed for SEM. All specimens were counted with a planimeter. We found that the specular microscope adequately analyzes the endothelial cell density in the central and paracentral cornea of a normal eye, but because of its small sampling area specular microscopic counts are subject to significant error when dealing with nonhomogeneous populations such as postoperative cases. We found the peripheral corneal endothelial density to be less than the central endothelial density. Furthermore, we found that we could maximize the accuracy of counting by using a variable frame in a nonhomogeneous population, counting a minimum of four photographs per specimen, analyzing different areas, and analyzing larger areas.

Entities:  

Mesh:

Year:  1979        PMID: 399798     DOI: 10.1016/s0161-6420(79)35343-x

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  The effects of corneal parameters on the assessment of endothelial cell density in the elderly eye.

Authors:  A Müller; J P Craig; C N Grupcheva; C N J McGhee
Journal:  Br J Ophthalmol       Date:  2004-03       Impact factor: 4.638

Review 2.  Review of corneal endothelial specular microscopy for FDA clinical trials of refractive procedures, surgical devices, and new intraocular drugs and solutions.

Authors:  Bernard E McCarey; Henry F Edelhauser; Michael J Lynn
Journal:  Cornea       Date:  2008-01       Impact factor: 2.651

3.  Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

Authors:  László Jr Módis; Eszter Szalai; Zsuzsa Flaskó; Gábor Németh
Journal:  Rom J Ophthalmol       Date:  2016 Apr-Jun

4.  Shrinkage in preparatory steps for SEM. A study on rabbit corneal endothelium.

Authors:  O A Jensen; J U Prause; H Laursen
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1981

5.  Quantitative and Morphological Corneal Endothelial Changes After Selective Laser Trabeculoplasty and Retinal Photocoagulation.

Authors:  Aran Kanagaratnam; Keith Ong
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 Jan-Feb

6.  Visualizing Micro-anatomical Structures of the Posterior Cornea with Micro-optical Coherence Tomography.

Authors:  Si Chen; Xinyu Liu; Nanshuo Wang; Xianghong Wang; Qiaozhou Xiong; En Bo; Xiaojun Yu; Shufen Chen; Linbo Liu
Journal:  Sci Rep       Date:  2017-09-07       Impact factor: 4.379

7.  Corneal endothelial cell loss after trabeculectomy and phacoemulsification in one or two steps: a prospective study.

Authors:  María Isabel Soro-Martínez; Juan Antonio Miralles de Imperial-Ollero; Miriam Pastor-Montoro; Gabriel Arcos-Villegas; Paloma Sobrado-Calvo; José María Ruiz-Gómez; Jaime Miralles de Imperial-Mora-Figueroa; María Paz Villegas-Pérez
Journal:  Eye (Lond)       Date:  2021-01-07       Impact factor: 3.775

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.