| Literature DB >> 3988841 |
Abstract
A comprehensive approach to the analysis of anticoagulant rodenticide residues in animal tissues based on high-performance liquid chromatography (HPLC) has been developed. Residues of warfarin, coumatetralyl, difenacoum, brodifacoum, bromadiolone, diphacinone and chlorophacinone were extracted with chloroformacetone (1:1, v/v). Extracts were cleaned-up by an integrated gel permeation and adsorption chromatographic procedure which divided the rodenticides into two groups. Residues were then determined and confirmed using normal-phase, ion-pair and weak ion-exchange HPLC techniques. Ion-pair gradient separation resolved all seven rodenticides in a single chromatographic analysis. UV detection methods were employed for all seven rodenticides. Use of a diode array detection system permitted additional confirmation of residues down to 0.1 mg kg-1 by matching UV spectra and derivatives of spectra. Sensitive fluorescence detection was possible for the coumarin-based rodenticides but not for diphacinone and chlorophacinone. Post-column pH-switching fluorescence detection methods were shown to be superior to other methods of fluorescence detection of coumarin-based rodenticides. Recoveries from spiked liver tissue were around 90% at levels from 0.05 to 1 mg kg-1. Detection limits of around 0.002 mg kg-1 for most rodenticides and of 0.01 mg kg-1 for warfarin could be achieved with animal tissue extracts.Entities:
Mesh:
Substances:
Year: 1985 PMID: 3988841 DOI: 10.1016/s0021-9673(01)90444-3
Source DB: PubMed Journal: J Chromatogr