Literature DB >> 3988841

High-performance liquid chromatographic strategies for the determination and confirmation of anticoagulant rodenticide residues in animal tissues.

K Hunter.   

Abstract

A comprehensive approach to the analysis of anticoagulant rodenticide residues in animal tissues based on high-performance liquid chromatography (HPLC) has been developed. Residues of warfarin, coumatetralyl, difenacoum, brodifacoum, bromadiolone, diphacinone and chlorophacinone were extracted with chloroformacetone (1:1, v/v). Extracts were cleaned-up by an integrated gel permeation and adsorption chromatographic procedure which divided the rodenticides into two groups. Residues were then determined and confirmed using normal-phase, ion-pair and weak ion-exchange HPLC techniques. Ion-pair gradient separation resolved all seven rodenticides in a single chromatographic analysis. UV detection methods were employed for all seven rodenticides. Use of a diode array detection system permitted additional confirmation of residues down to 0.1 mg kg-1 by matching UV spectra and derivatives of spectra. Sensitive fluorescence detection was possible for the coumarin-based rodenticides but not for diphacinone and chlorophacinone. Post-column pH-switching fluorescence detection methods were shown to be superior to other methods of fluorescence detection of coumarin-based rodenticides. Recoveries from spiked liver tissue were around 90% at levels from 0.05 to 1 mg kg-1. Detection limits of around 0.002 mg kg-1 for most rodenticides and of 0.01 mg kg-1 for warfarin could be achieved with animal tissue extracts.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3988841     DOI: 10.1016/s0021-9673(01)90444-3

Source DB:  PubMed          Journal:  J Chromatogr


  4 in total

1.  An enhancement of europium-/gadolinium- diphacinone -DL-histidine- cetylpyridine bromide system for the determination of diphacinone in serum.

Authors:  Meiqiang Cai; Xiaohong Chen; Micong Jin
Journal:  J Fluoresc       Date:  2011-02-22       Impact factor: 2.217

2.  Detection of anticoagulant rodenticides (4-hydroxycoumarins) by thin-layer chromatography and reversed-phase high-performance liquid chromatography with fluorescence detection.

Authors:  I Rengel; A Friedrich
Journal:  Vet Res Commun       Date:  1993       Impact factor: 2.459

3.  Chiral liquid chromatography-tandem mass spectrometry analysis of superwarfarin rodenticide stereoisomers - Bromadiolone, difenacoum and brodifacoum - In human plasma.

Authors:  Daniel G Nosal; Douglas L Feinstein; Richard B van Breemen
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2021-01-07       Impact factor: 3.318

4.  Separation and Quantification of Superwarfarin Rodenticide Diastereomers-Bromadiolone, Difenacoum, Flocoumafen, Brodifacoum, and Difethialone-in Human Plasma.

Authors:  Daniel G Nosal; Douglas L Feinstein; Luying Chen; Richard B van Breemen
Journal:  J AOAC Int       Date:  2020-06-01       Impact factor: 2.028

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.