Literature DB >> 3988695

Analysis of USP epinephrine injections for potency, impurities, degradation products, and d-enantiomer by liquid chromatography, using ultraviolet and electrochemical detectors.

R D Kirchhoefer, G M Sullivan, J F Allgire.   

Abstract

A liquid chromatographic (LC) method was adapted for the determination of epinephrine and related impurities in intravenous and cardiac injections; ultraviolet (UV) and electrochemical detectors (EC) were used in series. Epinephrine was determined and related impurities, i.e., adrenalone, epinephrine sulfonic acid, and norepinephrine, were detected directly in a small portion of the injection solution. Diastereoisomers of the epinephrine enantiomers were prepared by derivatization and determined by LC with a UV detector. The recovery of epinephrine added to epinephrine injection was 100%. The recovery of d-enantiomer from a d, l mixture was 100%. Impurities at levels less than 1% were easily detected. The LC method with UV detection is faster and more convenient than the USP XX method. In addition, impurities can be detected in the same portion of sample. The procedure is stability-indicating.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3988695

Source DB:  PubMed          Journal:  J Assoc Off Anal Chem        ISSN: 0004-5756


  1 in total

1.  Determination of the enantiomeric purity of epinephrine by HPLC with circular dichroism detection.

Authors:  Douglas Kirkpatrick; Jingyue Yang; Michael Trehy
Journal:  J Liq Chromatogr Relat Technol       Date:  2017-05-31       Impact factor: 1.312