Literature DB >> 3988686

Effect of breath-hold time on DLCO(SB) in patients with airway obstruction.

B L Graham, J T Mink, D J Cotton.   

Abstract

The single-breath diffusing capacity of the lung for CO [DLCO(SB)] is considered a measure of the conductance of CO across the alveolar-capillary membrane and its binding with hemoglobin. Although incomplete mixing of inspired gas with alveolar gas could theoretically influence overall diffusion, conventional calculations of DLCO(SB) spuriously overestimate DLCO(SB) during short breath-holding periods when incomplete mixing of gas within the lung might have the greatest effect. Using the three-equation method to calculate DLCO(SB) which analytically accounts for changes in breath-hold time, we found that DLCO(SB) did not change with breath-hold time in control subjects but increased with increasing breath-hold time in both patients with asthma and patients with emphysema. The increase in DLCO(SB) with increasing breath-hold time correlated with the phase III slope of the single-breath N2 washout curve. We suggest that in patients with ventilation maldistribution, DLCO(SB) may be decreased for the shorter breath-hold maneuvers because overall diffusion is limited by the reduced transport of CO from the inspired gas through the alveolar gas prior to alveolar-capillary gas exchange.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3988686     DOI: 10.1152/jappl.1985.58.4.1319

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  5 in total

1.  Are there sex differences in the capillary blood volume and diffusing capacity response to exercise?

Authors:  Melissa M Bouwsema; Vincent Tedjasaputra; Michael K Stickland
Journal:  J Appl Physiol (1985)       Date:  2016-12-08

2.  Quantification of single-breath underestimation of lung volume in emphysema.

Authors:  Fulvia Milite; David J Lederer; Jeremy A Weingarten; Pauline Fani; Anne M Mooney; Robert C Basner
Journal:  Respir Physiol Neurobiol       Date:  2008-12-25       Impact factor: 1.931

3.  Value of lung diffusing capacity for nitric oxide in systemic sclerosis.

Authors:  Giovanni Barisione; Alessandro Garlaschi; Mariaelena Occhipinti; Michele Baroffio; Massimo Pistolesi; Vito Brusasco
Journal:  Physiol Rep       Date:  2019-08

4.  Assessment of the alveolar volume when sampling exhaled gas at different expired volumes in the single breath diffusion test.

Authors:  Renato Prediletto; Edo Fornai; Giosuè Catapano; Cristina Carli
Journal:  BMC Pulm Med       Date:  2007-12-19       Impact factor: 3.317

5.  Effect of aerobic fitness on capillary blood volume and diffusing membrane capacity responses to exercise.

Authors:  Vincent Tedjasaputra; Melissa M Bouwsema; Michael K Stickland
Journal:  J Physiol       Date:  2016-05-12       Impact factor: 5.182

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.