Literature DB >> 3985405

Effects of intravenous anesthesia on VA/Q distribution: a study performed during ventilation with air and with 50% oxygen, supine and in the lateral position.

E Anjou-Lindskog, L Broman, M Broman, A Holmgren, G Settergren, G Ohqvist.   

Abstract

Distribution of ventilation and perfusion in relation to ventilation-perfusion ratio (VA/Q) were studied in 14 patients, with a mean age of 59 yr, before elective lung surgery, in the supine position when awake, during intravenous anesthesia and mechanical ventilation with air, after increasing the fraction of inspired oxygen (FIO2) to 0.5, and in the lateral position. Before anesthesia, small inert gas shunts and perfusion of low VA/Q regions, indicating some degree of VA/Q mismatch, were observed in several patients. After induction, FIO2 = 0.21, the major changes were a significant decrease in cardiac output and an increase in log SD for perfusion from 0.77 +/- 0.45 (SD) to 1.13 +/- 0.50 (SD), while the shunt remained low at 1% of cardiac output and arterial oxygen tension (PaO2) was unchanged. An increase to FIO2 = 0.5 induced only small changes with a shunt of 2.5% of cardiac output. In the lateral position, the shunt was 4.0% and increases in ventilation to high VA/Q regions were observed. The lack of marked changes in the VA/Q distribution after induction either could be a result of only minor alterations in the distribution of ventilation and perfusion or an effective vascular response to alveolar hypoxia (hypoxic pulmonary vasoconstriction, HPV).

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3985405

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  3 in total

Review 1.  Contribution of multiple inert gas elimination technique to pulmonary medicine. 6. Ventilation-perfusion relationships during anaesthesia.

Authors:  G Hedenstierna
Journal:  Thorax       Date:  1995-01       Impact factor: 9.139

Review 2.  Atelectasis formation during anesthesia: causes and measures to prevent it.

Authors:  G Hedenstierna; H U Rothen
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  Difference in the value of arterial and end-tidal carbon dioxide tension according to different surgical positions: Does it reliably reflect ventilation-perfusion mismatch?

Authors:  Jin Joo; Young Hee Kim; Jaemin Lee; Jong Ho Choi
Journal:  Korean J Anesthesiol       Date:  2012-09-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.