Literature DB >> 3984900

Holter recording during treadmill testing in assessing myocardial ischemic changes.

D Tzivoni, J Benhorin, A Gavish, S Stern.   

Abstract

One hundred forty-four patients underwent a Bruce protocol treadmill exercise test during which an electrocardiogram (ECG) was recorded simultaneously with a 2-channel Holter recorder with bipolar V3- and V5-like leads and by a conventional 12-lead system. Sixty-eight patients had no ST depression on either the Holter or on the 12-lead ECG during the exercise test, whereas in 70 patients ischemic changes were recorded by both methods; thus, in 138 of the 144 patients (96%), the results of the 2 tests were concordant. The severity of ST depression, as judged by the heart rate at which ischemic changes were first noted and the maximal ST depression observed, were similar on both recording systems. The Holter system identified 6 of the 7 patients whose ischemic changes were confined to the inferior wall on the 12-lead ECG. The addition of the V3 lead as a second ischemic lead increased the ischemia detection by 10%. Ninety-five patients also underwent coronary arteriography. In these patients the sensitivity of the Holter system during exercise in detecting significant coronary artery disease was 81% and that of 12-lead ECG was 84%, the specificity was 85% and 85%, respectively, and the positive predictive value 91% and 91%, respectively. Thus, the 2-channel Holter recording system with bipolar V3- and V5-like leads was as accurate as the 12-lead system in detecting ischemic changes during exercise and proved that ambulatory monitoring system can reliably reproduce ST segment.

Entities:  

Mesh:

Year:  1985        PMID: 3984900     DOI: 10.1016/0002-9149(85)90663-0

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Computerised analysis of ST segment changes in ambulatory electrocardiograms.

Authors:  S Akselrod; M Norymberg; I Peled; E Karabelnik; M S Green
Journal:  Med Biol Eng Comput       Date:  1987-09       Impact factor: 2.602

Review 2.  Value and limitations of ambulatory ECG monitoring for assessment of myocardial ischemia.

Authors:  D Tzivoni
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-07       Impact factor: 1.468

Review 3.  Silent ischaemia in the 1990s.

Authors:  D Tzivoni
Journal:  Drugs       Date:  1991       Impact factor: 9.546

Review 4.  The combination of antianginal drugs: effects and indications.

Authors:  P R Lichtlen
Journal:  Cardiovasc Drugs Ther       Date:  1988-05       Impact factor: 3.727

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.