Literature DB >> 3979408

Measurements of the rubidium isotopic activities and the elution parameters of 81mKr generators using a standardized 114mIn source.

N R Williams, P O Childs, D A Causer, A B Mostafa.   

Abstract

A method is described for measuring a number of parameters associated with an inorganic ion-exchange krypton generator. These are the activities of rubidium isotopes in inorganic ion-exchange krypton generators, the 81mKr extraction rate, the 81mKr activity delivered to patients during ventilation studies, the elution efficiency, and the radionuclide purity of the eluted gas. The method is based on the calibration of detectors, Ge(Li) and NaI(Tl), with a standardized 114mIn source at matching photon energies. The average activities present in our generators at the end of bombardment (EOB) were 14.6 +/- 3.8 mCi (81Rb), 6.2 +/- 1.6 mCi (82mRb) and 53 +/- 9.4 microCi (83Rb). The 81mKr extraction rate 2 h post-EOB was 10.2 +/- 2.3 mCi/min at an air flowrate of 1 l/min. The 81mKr activity delivered to patients during a ventilation study was 91 +/- 16 mCi. The elution efficiency of the generators averaged 50% +/- 7% at an air flowrate of 1 l/min. The eluted gas contained Rb radioisotopic impurities in trace quantities of approximately 0.06 microCi/l.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3979408     DOI: 10.1007/bf00261760

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  A minigenerator for the production of krypton-81m and its applications.

Authors:  L W Mayron; E Kaplan; L G Colombetti; A M Friedman; J E Gindler
Journal:  Int J Nucl Med Biol       Date:  1975-01

2.  Continuous radionuclide generation. I. Production and evaluation of a 81mKr minigenerator.

Authors:  L G Colombetti; L W Mayron; E Kaplan; W E Barnes; A M Friedman; J E Gindler
Journal:  J Nucl Med       Date:  1974-10       Impact factor: 10.057

3.  81mKr generator and its uses in cardiopulmonary studies with the scintillation camera.

Authors:  T Jones; J C Clark; J M Hughes; D Y Rosenzweig
Journal:  J Nucl Med       Date:  1970-03       Impact factor: 10.057

4.  Lung function studies using short-lived 81mKr and the scintillation camera.

Authors:  Y Yano; J McRae; H O Anger
Journal:  J Nucl Med       Date:  1970-11       Impact factor: 10.057

5.  Cyclotron isotopes and radiopharmaceuticals--XXX. Aspects of production, elution and automation of 81Rb-81Kr generators.

Authors:  T Moroji; R M Lambrecht; A P Wolf; M L Thakur
Journal:  Int J Appl Radiat Isot       Date:  1980-01

6.  Ventilation imaging with Kr-81m. A comparison with Xe-133.

Authors:  T R Miller; D R Biello; J I Lee; H H Davis; A G Mattar; G J Ehrhardt; B A Siegel
Journal:  Eur J Nucl Med       Date:  1981-01

7.  81mKr gas generator for lung ventilation study.

Authors:  T Koyama; T Koyama; Y Hirokawa; Y Yoshizawa; H Noma; T Horiguchi; Y Kiso; H Hasai; H Takemi
Journal:  Eur J Nucl Med       Date:  1980-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.