Literature DB >> 3976807

Effects of intraocular irrigating solutions on the corneal endothelium after in vivo anterior chamber irrigation.

D B Glasser, M Matsuda, J G Ellis, H F Edelhauser.   

Abstract

We used wide-field specular microscopy and corneal pachymetry to evaluate the effect of anterior chamber irrigation with BSS and BSS Plus on the corneal endothelium of cats. Endothelial changes were quantitated by computerized morphometric analysis of individual cells. After short-term (15 and 30 minutes) and long-term (one and two hours) irrigation, endothelial cell density remained unchanged. Corneal thickness increased significantly in the BSS group after one hour of irrigation. BSS Plus caused minimal changes in endothelial morphologic characteristics regardless of the irrigation time. By comparison, BSS caused a significant increase in the coefficient of variation of cell area (polymegethism) and a decrease in the percentage of hexagonal cells (pleomorphism). These changes were more prominent after prolonged irrigation. The morphologic changes caused by BSS irrigation are indicative of a stressed endothelial monolayer that may be more susceptible to additional surgical trauma.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3976807     DOI: 10.1016/0002-9394(85)90363-0

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  17 in total

1.  Endothelial cell density and corneal pachometry after no-stitch, small-incision cataract surgery.

Authors:  M Amon; R Menapace; U Radax; P Papapanos
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

2.  Comparative analysis of coaxial phacoemulsification with 2.2- and 2.8-mm clear corneal incisions.

Authors:  Harinder Singh Sethi; Komal Saluja; Mayuresh P Naik
Journal:  Int Ophthalmol       Date:  2017-01-31       Impact factor: 2.031

3.  Intraocular irrigating solutions and barrier function of retinal pigment epithelium.

Authors:  M Araie; M Kimura
Journal:  Br J Ophthalmol       Date:  1997-02       Impact factor: 4.638

4.  Automated morphometry of corneal endothelial cell: use of video camera and video tape recorder.

Authors:  O Nishi; K Hanasaki
Journal:  Br J Ophthalmol       Date:  1988-01       Impact factor: 4.638

5.  Corneal preservation at 4 degrees C with chondroitin sulfate containing medium.

Authors:  R L Lindstrom; D J Doughman; D L Skelnik; E A Mindrup
Journal:  Trans Am Ophthalmol Soc       Date:  1987

6.  Intraocular irrigating solutions: a comparison of Hartmann's lactated Ringer's solution, BSS and BSS Plus.

Authors:  R M Nuyts; H F Edelhauser; G P Holley
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-10       Impact factor: 3.117

Review 7.  Advances in corneal preservation.

Authors:  R L Lindstrom
Journal:  Trans Am Ophthalmol Soc       Date:  1990

8.  Temporary corneal oedema after acute intake of alcohol.

Authors:  T Shiono; Y Asano; T Hashimoto; K Mizuno
Journal:  Br J Ophthalmol       Date:  1987-06       Impact factor: 4.638

9.  Effects of irrigation solutions on corneal endothelial function.

Authors:  M I Yagoubi; W J Armitage; J Diamond; D L Easty
Journal:  Br J Ophthalmol       Date:  1994-04       Impact factor: 4.638

10.  Comparison of the effects of intraocular irrigating solutions on the corneal endothelium in intraocular lens implantation.

Authors:  M Matsuda; S Kinoshita; Y Ohashi; Y Shimomura; N Ohguro; H Okamoto; T Omoto; H Hosotani; H Yoshida
Journal:  Br J Ophthalmol       Date:  1991-08       Impact factor: 4.638

View more