Quality control of multichannel hematology analyzers: evaluation of Bull's algorithm.

G S Cembrowski, J O Westgard.   

Abstract

Bull's algorithm has been evaluated by computer simulation studies. Varying amounts of systematic analytic error were simulated in either hemoglobin (Hgb), red blood cell count (RBC), or mean corpuscular volume (MCV) with the resulting red blood cell indices averaged in batches of 20 using Bull's algorithm. The number of average indices outside the limits of 0.97 means and 1.03 means (means = stable patient mean index) was tabulated and plotted against the size of the systematic shift, expressed in multiples of the long-term analytic standard deviation (SD). The resulting plots, called power functions, show that Bull's algorithm can detect large shifts effectively and that its power increases with increasing batch number. Shifts less than 2 SD rarely are detected. The minimum error that is detected 50% of the time after nine consecutive batches is shown below: (Formula: see text) The simulation of populations with outlying indices, e.g., neonates and oncology patients, resulted in both decreased and increased power, depending on the proportion of outliers averaged, the index averaged, and the direction of the shift.

Entities:  

Mesh:

Year:  1985        PMID: 3976570     DOI: 10.1093/ajcp/83.3.337

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Rationale for using insensitive quality control rules for today's hematology analyzers.

Authors:  George S Cembrowski; B Smith; D Tung
Journal:  Int J Lab Hematol       Date:  2010-12       Impact factor: 2.877

2.  Improving quality control for in-clinic hematology analyzers: Common myths and opportunities.

Authors:  Helen T Michael; Mary B Nabity; C Guillermo Couto; Andreas Moritz; John W Harvey; Dennis B DeNicola; Jeremy M Hammond
Journal:  Vet Clin Pathol       Date:  2022-09       Impact factor: 1.333

3.  Mean platelet size related to glycoprotein-specific autoantibodies and platelet-associated IgG.

Authors:  K Javela; R Kekomäki
Journal:  Int J Lab Hematol       Date:  2007-12       Impact factor: 2.877

4.  Failure of internal quality control in detecting significant reagent lot shift in serum creatinine measurement.

Authors:  Xiaoting Chen; Jia Wang; Wei Zhang; Erfu Xie; Bingfeng Zhang; Hua-Guo Xu
Journal:  J Clin Lab Anal       Date:  2019-08-02       Impact factor: 2.352

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.