Literature DB >> 3973300

Assessment of the ductus arteriosus in preterm infants utilizing suprasternal two-dimensional/Doppler echocardiography.

G W Vick, J C Huhta, H P Gutgesell.   

Abstract

Evaluation for patent ductus arteriosus by both Doppler examination and direct two-dimensional echocardiographic visualization has been reported in infants and children. However, visualization of a patent ductus arteriosus in preterm infants with lung disease has been difficult. Using a recently developed 7.5 MHz mechanical scanner with interfaced two-dimensional directed pulsed Doppler ultrasonography, 36 examinations were performed from a suprasternal approach in 27 patients (age range 1 day to 3 months, mean 18 days; weight range 490 to 2,500 g, mean 1,260). Complete imaging for evaluation of patency of the ductus arteriosus was successful in 33 (92%) of 36 examinations, and imaging of the pulmonary end of the ductus arteriosus was successful in all. In 18 examinations, the ductus arteriosus was closed by both two-dimensional echocardiography and Doppler examination. In four cases the ductus arteriosus was widely patent by both two-dimensional echocardiography and Doppler examination. Eleven echocardiographic examinations revealed a narrowed ductus arteriosus, and of these, 10 (91%) showed Doppler findings of patent ductus arteriosus. It is concluded that combined two-dimensional/Doppler echocardiographic assessment allows confident detection of both a large unrestrictive and a small, stenotic patent ductus arteriosus in preterm infants with lung disease.

Entities:  

Mesh:

Year:  1985        PMID: 3973300     DOI: 10.1016/s0735-1097(85)80442-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

Review 1.  Contributions of the Texas Children's Hospital Pediatric Cardiology Program to the field of pediatric cardiology.

Authors:  J T Bricker
Journal:  Tex Heart Inst J       Date:  1997

Review 2.  Echocardiography in the diagnosis of thoracic aortic pathology.

Authors:  F D Tice; J Kisslo
Journal:  Int J Card Imaging       Date:  1993

Review 3.  Diagnosis of patent ductus arteriosus in the preterm newborn.

Authors:  N Evans
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

4.  Re-evaluation of the left atrial to aortic root ratio as a marker of patent ductus arteriosus.

Authors:  P Iyer; N Evans
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-03       Impact factor: 5.747

5.  Sensitivity, specificity and predictive value of clinical findings, m-mode echocardiography and continuous-wave Doppler sonography in the diagnosis of symptomatic patent ductus arteriosus in preterm infants.

Authors:  C Kupferschmid; D Lang; F Pohlandt
Journal:  Eur J Pediatr       Date:  1988-04       Impact factor: 3.183

6.  Two-dimensional and Doppler echocardiographic assessment of variably shaped ductus arteriosus by the parasternal approach.

Authors:  S Hiraishi; Y Horiguchi; N Fujino; Y Agata; H Kawai; M Ohe; K Yashiro
Journal:  Pediatr Cardiol       Date:  1991-01       Impact factor: 1.655

7.  Ductal Flow Ratio as Measure of Transition in Preterm Infants After Birth: A Pilot Study.

Authors:  Emma Brouwer; Ronny Knol; Nathan D Hahurij; Stuart B Hooper; Arjan B Te Pas; Arno A W Roest
Journal:  Front Pediatr       Date:  2021-07-19       Impact factor: 3.418

  7 in total