Construction and performance of a variable-frequency phase-modulation fluorometer.

J R Lakowicz, B P Maliwal.   

Abstract

We describe the construction and performance of a variable-frequency phase-modulation fluorometer. This instrument, which provides modulation frequencies from 1 to 200 MHz, was constructed using commercially available components. To facilitate the introduction of these instruments into other laboratories we describe in detail the chosen components and the principles of operation. The present light source is a continuous-wave helium-cadmium laser, which provides convenient excitation wavelengths of 325 and 442 nm. Modulation of the incident light is provided by one of several electro-optic modulators. The extent of modulation ranges from 1.0 to 0.2 as the frequency increases from 1 to 200 MHz. Phase angles and demodulation factors are measured using the cross-correlation method. The closely spaced frequencies are provided by two direct frequency synthesizers. The phase and modulation measurements are accurate to 0.2 degrees and 0.002, respectively, from 1 to 200 MHz. This accuracy allows considerable resolution of complex decay laws. The usefulness of frequency-domain fluorometry for the resolution of multiexponential decays is illustrated by the analysis of several difficult mixtures. As examples, we resolved a two-component mixture of anthracene (4.1 ns) and 9,10-diphenylanthracene (6.3 ns), and confirmed that the intensity decay of NADH in aqueous buffer is at least a double exponential (0.2 and 0.86 ns). We also resolved an especially difficult mixture of anthracene (4.1 ns) and 9-methylanthracene (4.5 ns), and a three-component mixture with decay times of 1.3, 4.1 and 7.7 ns. Frequency-domain fluorometers appear to be particularly useful for determination of complex decays of fluorescence anisotropy. This capability is illustrated by the determination of rotational correlation times as short as 47 ps for p-bis[2-(5-phenyloxazolyl)]benzene (POPOP) in hexane at 40 degrees C, and by the resolution of the two correlation times of anisotropic rotators such as perylene and 9-aminoacridine. Resolution of two anisotropy decay times for 9-aminoacridine is a difficult test because these correlation times differ by less than 2-fold. The resolution of multiexponential decays of intensity and anisotropy possible with this instrument is at least equivalent to that obtained using state-of-the-art time-resolved instruments based on mode-locked laser sources. The ease and rapidity of frequency-domain measurements, the relative simplicity of the equipment, the accuracy of the measurements and the lack of significant systematic errors indicate that frequency-domain fluorometry will be widely useful in chemical and biochemical research.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3971026     DOI: 10.1016/0301-4622(85)85007-9

Source DB:  PubMed          Journal:  Biophys Chem        ISSN: 0301-4622            Impact factor:   2.352


  55 in total

1.  On the possibility of long-wavelength long-lifetime high-quantum-yield luminophores.

Authors:  J R Lakowicz; G Piszczek; J S Kang
Journal:  Anal Biochem       Date:  2001-01-01       Impact factor: 3.365

2.  Lifetime-based pH sensors: indicators for acidic environments.

Authors:  H J Lin; H Szmacinski; J R Lakowicz
Journal:  Anal Biochem       Date:  1999-04-10       Impact factor: 3.365

3.  Fluorescence lifetime characterization of novel low-pH probes.

Authors:  H J Lin; P Herman; J S Kang; J R Lakowicz
Journal:  Anal Biochem       Date:  2001-07-15       Impact factor: 3.365

4.  Fluorescence properties of albumin blue 633 and 670 in plasma and whole blood.

Authors:  O O Abugo; P Herman; J R Lakowicz
Journal:  J Biomed Opt       Date:  2001-07       Impact factor: 3.170

5.  High-molecular-weight protein hydrodynamics studied with a long-lifetime metal-ligand complex.

Authors:  Jung Sook Kang; Grzegorz Piszczek; Joseph R Lakowicz
Journal:  Biochim Biophys Acta       Date:  2002-06-03

6.  Real-time background suppression during frequency domain lifetime measurements.

Authors:  Petr Herman; Badri P Maliwal; Joseph R Lakowicz; Baldri P Maliwal
Journal:  Anal Biochem       Date:  2002-10-01       Impact factor: 3.365

7.  Effects of metallic silver particles on resonance energy transfer in labeled bovine serum albumin.

Authors:  Joanna Malicka; Ignacy Gryczynski; Jozef Kusba; Yibing Shen; Joseph R Lakowicz
Journal:  Biochem Biophys Res Commun       Date:  2002-06-21       Impact factor: 3.575

8.  Fluorescence lifetime imaging.

Authors:  J R Lakowicz; H Szmacinski; K Nowaczyk; K W Berndt; M Johnson
Journal:  Anal Biochem       Date:  1992-05-01       Impact factor: 3.365

9.  Resolution of multicomponent fluorescence emission using frequency-dependent phase angle and modulation spectra.

Authors:  J R Lakowicz; R Jayaweera; H Szmacinski; W Wiczk
Journal:  Anal Chem       Date:  1990-09-15       Impact factor: 6.986

10.  Model-independent analysis of the orientation of fluorescent probes with restricted mobility in muscle fibers.

Authors:  R E Dale; S C Hopkins; U A an der Heide; T Marszałek; M Irving; Y E Goldman
Journal:  Biophys J       Date:  1999-03       Impact factor: 4.033

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.