Literature DB >> 3967429

Posterior stabilization of pelvic fractures by use of threaded compression rods. Case reports and mechanical testing.

J A Shaw, D E Mino, F W Werner, D G Murray.   

Abstract

Threaded compression rods were placed between the posterior-superior spines as a means of posterior stabilization of pelvic fractures. To document the increase in sacroiliac stability afforded by this technique, biomechanical testing was performed. Malgaigne-type fractures with sacroiliac disruptions were created in four cadaver pelvises. The fractures were stabilized with anterior frames of the Slatis or Pittsburgh type and subjected to longitudinal and torsional loading patterns on an Instron machine. The anterior fixation was then augmented with threaded compression rods placed between the posterior-superior spines to compress the disrupted sacroiliac joints, and repeat testing was conducted. Anterior frames alone were found to provide little stabilization of the disrupted sacroiliac joints with either longitudinal or torsional loading. Markedly improved stabilization in both loading modes was achieved with posterior augmentation. Two typical cases are presented to demonstrate that posterior stabilization is as efficacious in clinical practice as in the biomechanics laboratory.

Entities:  

Mesh:

Year:  1985        PMID: 3967429

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Biomechanical analysis of a transiliac internal fixator.

Authors:  Thomas Dienstknecht; Arne Berner; Andreas Lenich; Johannes Zellner; Michael Mueller; Michael Nerlich; Bernd Fuechtmeier
Journal:  Int Orthop       Date:  2011-04-08       Impact factor: 3.075

2.  [Posterior approaches to the pelvic ring].

Authors:  W Lehmann; L Großterlinden; J M Rueger
Journal:  Unfallchirurg       Date:  2013-03       Impact factor: 1.000

Review 3.  [Biomechanical principles for treatment of osteoporotic fractures of the pelvis].

Authors:  A Gänsslen
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

4.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

Review 5.  [Sacrum fractures and lumbopelvic instabilities in pelvic ring injuries: classification and biomechanical aspects].

Authors:  M Dudda; M Hoffmann; T A Schildhauer
Journal:  Unfallchirurg       Date:  2013-11       Impact factor: 1.000

6.  Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

Authors:  Jonathan M Vigdorchik; Amanda O Esquivel; Xin Jin; King H Yang; Ndidi A Onwudiwe; Rahul Vaidya
Journal:  J Orthop Surg Res       Date:  2012-09-27       Impact factor: 2.359

7.  Evaluation of a minimally invasive procedure for sacroiliac joint fusion - an in vitro biomechanical analysis of initial and cycled properties.

Authors:  Derek P Lindsey; Luis Perez-Orribo; Nestor Rodriguez-Martinez; Phillip M Reyes; Anna Newcomb; Alexandria Cable; Grace Hickam; Scott A Yerby; Neil R Crawford
Journal:  Med Devices (Auckl)       Date:  2014-05-15

8.  Biomechanical evaluation of location and mode of failure in three screw fixations for a comminuted transforaminal sacral fracture model.

Authors:  Brett D Crist; Ferris M Pfeiffer; Michael S Khazzam; Rebecca A Kueny; Gregory J Della Rocca; William L Carson
Journal:  J Orthop Translat       Date:  2018-07-10       Impact factor: 5.191

9.  Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study.

Authors:  Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; R Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer
Journal:  Medicina (Kaunas)       Date:  2021-12-16       Impact factor: 2.430

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.