Literature DB >> 3967428

Interobserver variability in interpreting radiographic lucencies about total hip reconstructions.

R A Brand, S A Yoder, D R Pedersen.   

Abstract

Radiographs are commonly used to identify the loosened total hip reconstruction (THR), to plan revision surgery, and to evaluate long-term follow-up patients for study purposes. Interobserver variability was studied in an attempt to interpret 63 random follow-up films in a group of 93 patients eight to 12 years post-THR. Nine observations were made on the acetabular and femoral sides of the reconstructions on all films for a total of 567 observations. There was considerable disagreement in observations of the acetabular lucencies; a consensus of all three observers was obtained only 46% of the time. There was more uniform agreement among observers (87%) in analyzing the femoral side, although agreement was most frequent when there was no lucency. There was no difference in observer variables when greater lucencies were reported by one or more observers than when there were smaller lucencies. It was concluded that a single observer can reliably record a femoral observation of no lucency and, making allowances for the Mach effect, can reliably distinguish the presence or absence of a lucency. However, a single observer may not be able to make observations of acetabular lucencies with great reliability and, in contrast to femoral lucencies, a single observer may be less reliable in recording acetabular lucencies over 2 mm as compared with those under 2 mm.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3967428

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  The prevalence of groin pain after metal-on-metal total hip arthroplasty and total hip resurfacing.

Authors:  Robert B Bartelt; Brandon J Yuan; Robert T Trousdale; Rafael J Sierra
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

2.  J. Wilson-MacDonald and E. Morscher: Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  B Mjöberg
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure?

Authors:  Ryan D Bauman; Derek R Johnson; Travis J Menge; Raymond H Kim; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

4.  Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs.

Authors:  D Kneif; M Downing; G P Ashcroft; P Gibson; D Knight; W Ledingham; J Hutchison
Journal:  Int Orthop       Date:  2005-04-02       Impact factor: 3.075

5.  Custom cementless THA in patients with skeletal dysplasia results in lower apparent revision rates than other types of femoral fixation.

Authors:  Mathew D Sewell; Sammy A Hanna; Sarah K Muirhead-Allwood; Stephen R Cannon; Timothy W R Briggs
Journal:  Clin Orthop Relat Res       Date:  2010-11-02       Impact factor: 4.176

6.  The Müller self-locking cemented total hip prosthesis with polyethylene liner: After twenty years, what did they become?

Authors:  Roger Erivan; Guillaume Villatte; Youcef Reda Khelif; Bruno Pereira; Myriam Galvin; Stéphane Descamps; Stéphane Boisgard
Journal:  Int Orthop       Date:  2016-04-25       Impact factor: 3.075

7.  Cemented total hip replacement cable debris and acetabular construct durability.

Authors:  Aaron J Altenburg; John J Callaghan; Tameem M Yehyawi; Douglas R Pedersen; Steve S Liu; Jessica A Leinen; Kevin A Dahl; Devon D Goetz; Thomas D Brown; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2009-07       Impact factor: 5.284

8.  Cortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up.

Authors:  Michael W Maier; Marcus R Streit; Moritz M Innmann; Marlis Krüger; Jan Nadorf; J Philippe Kretzer; Volker Ewerbeck; Tobias Gotterbarm
Journal:  BMC Musculoskelet Disord       Date:  2015-12-01       Impact factor: 2.362

9.  Acoustic monitoring (RFM) of total hip arthroplasty - Results of a cadaver study.

Authors:  A C Unger; H Cabrera-Palacios; A P Schulz; Ch Jürgens; Andreas Paech
Journal:  Eur J Med Res       Date:  2009-06-18       Impact factor: 2.175

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.